Omron H7EC Manual page 102

Self-powered totalizer
Hide thumbs Also See for H7EC:
Table of Contents

Advertisement

Settings for All Functions
Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. When using
as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure
given on page 124.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Power ON
See note 1.
See note 2.
3 s min.
3 s min.
Input mode
Output mode
C-108
Multifunction Preset Counter
For details on operations in run mode, refer to page 25.
Note: 1. If the mode is switched to the function setting mode during operation, operation will con-
tinue.
2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the counter is reset
(present value initialized and output turned OFF) on returning to run mode.
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by
Set each setting item using the
See note 3.
See note 4.
See note 4.
(UP)
(DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
Note 4: Displayed for output modes other than K-2, D, L, and H only.
(N)
(F)
(C)
Note: 5. Display only when the input mode is UP/DOWN A, B,
See note 6.
or C with 6-digit models (with H7CX-AU@/-AW@
One-shot
models only for H).
output
time
(0.01s)
(0.50s) (99.99s)
Note: Displayed only when the output mode is C, R, K-1, P,
Q, A, or K-2.
Counting
speed
(30Hz)
(5kHz)
Reset input
signal
width
(20ms)
(1ms)
Decimal
See note 7.
point
position
No decimal
point
Prescale
See note 7.
value
(0.001)
(1.000)
NPN/PNP
input mode
(NPN
(PNP
input)
input)
Display color
(Red)
(Green)
(Red-green) (Green-red)
Note: Displayed for terminal-block models (except H7CX-A11@) only.
Output
allocation
Note: Displayed for H7CX-AU@ models only.
Key protect
level
(KP-1)
(KP-2)
H7CX (Counter Function)
r
keys. (
key only for 6-digit models)
See note 5.
(R)
(K-1)
(P)
(Q)
(A)
(K-2)
One digit after
Two digits after
decimal point
decimal point
(99.999)
[9.999]
(KP-3)
(KP-4)
(KP-5)
will not be displayed.
Note 3:
When using as a dual counter:
See note.
(Addition) (Subtraction)
Note: Displayed for output modes
other than K-2, D, L, and H
only.
See note 5.
See note 5.
See note 5.
(D)
(L)
(H)
Note 6:
When using as a 2-stage counter:
One-
shot
(0.01s)
(0.50s) (99.99s)
output
Note: Displayed only when the
2 time
output mode is C, R, K-1,
P, Q, A, or K-2.
One-
shot
(Outputs held)
(0.01s) (99.99s)
output
If the output time is 0.00, hold is
1 time
displayed.
Note 1: Displayed for output modes
other than D, L, and H.
When using as a
Note 2: HOLD cannot be set when the
batch counter:
output mode is K-2.
One-
shot
(0.01s)
(0.50s) (99.99s)
output
Note: Displayed only when the output
2 time
mode is C, R, K-1, P, Q, A, or K-2.
Three digits after
decimal point
Note 7: The displays for 4-digit models are shown inside
parentheses.
Dual count
calculating mode