Conversion From Ng To Lpg - Regency Panorama PG33NG4-R Owners & Installation Manual

Gas inbuilt
Table of Contents

Advertisement

installation
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT
Conversion Kit Contains:
Qty.
Part #
Description
1
904-163
Burner Orifi ce #54
1
904-529
5/32" Allen Key
1
918-590
Label "Converted to LP"
1
908-528
Red "LPG" label
1
910-037
#30 ULPG Pilot Orifi ce
1
918-576
Instruction Sheet
1)
Shut off the gas supply and unplug the
power cord.
2)
Carefully remove the glass, logs and
lava rock.
3)
Remove burner.
4)
Remove burner orifi ce with a 1/2"
wrench and discard. Use a wrench to
hold on to the elbow behind the orifi ce.
5)
Reinstall new burner orifi ce stamped #54
and tighten.
6)
Pull out the pilot hood by hand.
Pilot
Hood
918-576
24
PG33 Conversion Kit #433-968 from NG to LPG
Conversion Kit #433-968 for NG to LPG
IF IN DOUBT DO NOT DO THIS CONVERSION !!
DO NOT DO THIS CONVERSION !!
Pilot
Hood
removed
Pilot
Orifi ce
7)
Remove the pilot orifi ce with the allen
key.
8)
Put in the new LPG orifi ce with the allen
key. Then put back the pilot hood.
Burner Orifi ce
9)
Adjust the burner aeration setting to
12.7mm and re-install the burner.
10) Open the bottom louver.
11) Stick the conversion label "This unit has
12) Replace the yellow "NG" label with the
13) Remove the screw from the module and
14) Pull out the 2 orange wires attached to
15) Carefully pull out the control box.
16) Remove the heat shield from the control
Note: The control box is held in place with
1
PG33-4 / P33-3
been converted to LPG" over top of the
serial number decal.
red "LPG" label.
pull off the module cover.
screw
module cover
the valve, and the connector from the
module.
orange connector
connector
wires
box by removing the 2 screws.
velcro.
control box
heat shield
Regency PG33NG4-R Gas Inbuilt
12/06/06

Advertisement