Quantum LTO-3 Model B Installation Manual page 19

1u rackmount enclosure
Table of Contents

Advertisement

Figure 23 Installing the Rack
Rails in the Back of the Rack
Installing the 1U Rackmount Enclosure in a Rack
LTO-3 (Model B), LTO-4 (Model B), LTO-5, LTO-6, and LTO-7
Note: To remove the rail for repositioning, push the spring-loaded tab on the outside
of the rack rail and slide rearward.
The rail installation is complete. Continue with
Installing in a Rack with 10-32 in. Threaded Holes
For installation in racks with 10-32 threaded holes in the vertical mounting bars, the
pins supplied on the rails must be removed. The rails will be attached with user-supplied
10-32 x.375 screws.
1 Remove the pins and threaded plates from both ends of each rack rail (see
Figure
24). These pieces will not be used.
Spring-loaded
tab
Completing the Installation
on page 22.
19