Parameters
Voltage Monitor
Current Monitor
Protection
Interface
Dimension
Weight
AC Input
*1, Typical parameter values in case of the 45-100HZ
*2, The scope of read-back resistance is( 1/(1/R+(1/R)*0.2%+0.01),1/(1/R-(1/R)*0.2%-0.01)
Test condition: The voltage/current input is no less than 10% FS.
Parameter
Parameter
CC mode *1
CR mode *2
CP mode
Crest Factor(CF)
Meter (continue)
S(VA),Q(VAR),P(W),Ip+,Ip-,Freq,THDv,CF,PF,R,FFT
OCP:≈110Arms,OVP:≈430Vrms,OPP:≈9.5kW,OTP:85℃
600.00mm(W) * 1475.01mm(H) *841.1mm(D)
Voltage
Frequency
Working
current
AC Section
Input voltage
Input current
Input power
Frequency
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Copyright © ITECH Electronic Co., Ltd.
Other
±600v/±10V(Isolation)
±300A/±10V(Isolation)
GPIB, USB, LAN
160KG
100-240V AC
47-63 Hz
<7.6A(110V), <3.8A(220V)
50~420Vrms , 600V peak
0~120Arms ,360Apeak
0-10.8kW
45~450Hz
0.1~120Arms
20mA
± (0.5%+0.5%FS)
0.5Ω~416.6Ω
16bit
0.2% +0.02S
10.8kW
3W
0.5%+0.5%FS
1.414~5.0
www.tehencom.com
Technical Specifications
IT8626 V1.3
89