2.1.8
Never exceed the maximum platform capacity, as indicated on the decals and machine serial plate.
2.1.9
Never position any part of the Niftylift within 4.0m, (12ft) of any electrical power line, conductor or
similar not exceeding 66kV. (Minimum span 125m) Other distances for increased voltages and
different spans are given in NZECP 34:1993
2.1.10
On entering the platform, ensure that the drop down entry bar is closed afterwards.
2.1.11
Use of an approved safety belt and lanyard, hardhat and appropriate safety clothing is mandatory.
Fasten harness to designated harness securing points within the platform and do not remove until
leaving the platform whilst in the stowed position.
2.1.12
2.1.13
Do not use the platform levelling system to artificially increase the outreach of the platform. Never use
boards or ladders in the platform to achieve the same result.
2.1.14
Do not use the platform to lift overhanging or bulky items that may exceed the maximum capacity or
carry objects that may increase the wind loading on the platform. (e.g. Notice boards etc.)
2.1.15
The Niftylift shall not be operated from a position on trucks, trailers, railway cars, floating vessels,
scaffolds or similar equipment unless Niftylift Ltd in Great Britain approves the application in writing.
2.1.16
Always check the area below and around the platform before lowering or slewing to ensure that it is
clear of personnel and obstructions. Care should be taken when slewing out into areas where there
may be passing traffic. Use barriers to control traffic flow or prevent access to the machine.
2.1.17
Stunt driving and horseplay, on or around the Niftylift, shall not be permitted
2.1.18
When other moving equipment and vehicles are present, special precautions shall be taken to comply
with local ordinances or safety standards established for the work place. Warnings such as, but not
limited to, flags, roped off areas, flashing lights and barricades shall be used.
2.1.19
It shall be the responsibility of the user to determine the hazard classification of any particular
atmosphere or location. Aerial platforms operated in hazardous locations shall be approved and of the
type required. (For the USA refer to ANSI/NFPA 505-1987.)
2.1.20
The operator shall immediately report to his supervisor any potentially hazardous location(s)
(environment) which become evident during operation.
2.1.21
If an operator encounters any suspected malfunction of the Niftylift or any hazard or potentially unsafe
condition relating to capacity, intended use or safe operation he shall cease operation of the Niftylift
and request further information as to safe operation from his management, or owner, dealer or
manufacturer before further operation of the Niftylift.
English/USA – 01/10
Issue 06
THIS MACHINE IS NOT INSULATED.
If in doubt, contact the appropriate authorities.
Always remain standing within the platform. Do not attempt to increase your height or
reach by standing and/or climbing on the platform guardrails or any other object.
KEEP YOUR FEET ON THE PLATFORM FLOOR. Do not sit, stand or climb on the
guardrail, mid rail or boom linkage. Use of planks, ladders or any other devices on the
Niftylift for achieving additional height or reach shall be prohibited.