Make sure that any hot parts of the
generating sets are not in contact with any
flammable material.
Never fill up the fuel tank while the engine is
running.
Never touch the generating sets or the wiring
connections with wet hands.
Never replace the fuses or the cut-out
switches
with
others
amperage.
Should any electrical part need checking, this
must only be done with the engine turned off
and by specialised personnel.
Vers. 001
GB
The
compliance with the safety standards listed in the
EEC statement of compliance.

6 USING THE GENERATING SET

6.1 Starting up the generating set

having
higher
The generating sets are provided with an
electronic remote control panel which allows you
to perform starting up / turning off operations and
to check their running conditions.
The panel controls are:
1 ON/OFF switch
2 Display unit
3 High temperature indicator
4 Engine minimum oil level indicator
5 Startup failed
6 Generator running (flashing)
7 Engine oil change indicator
8 Fuel warning light
9 Display time changeover switch
10 Reset
Set the startup switch (Fig.30 Ref.1) to its "ON"
position. The message "WAIT" will be displayed
for 8 seconds. After this time, the electronic
control panel will start the first automatic
procedure for starting up the generating set. If
the engine starts up at the end of this phase, the
"generator running" indicator light (Fig.30 Ref.6)
will start to flash.
Should the engine not start up, this automatic
procedure will be repeated up to 4 times.
If, at the end of a complete cycle, the engine has
not yet started up, the "startup failed" indicator
(Fig.30 Ref.5) will light up to signify that the
generating set has failed to start up.
If the "startup failed" indicator (Fig.30 Ref.5) light
only stays lit, you can repeat the procedure
several times. If the generating set has not
started up after several attempts, contact the
manufacturer's After-sales service. Should the
battery be flat, you can start the generating set
by hand, using the handle of the engine coil
winding (Fig.31 Ref.1) after setting the selector
switch to "ON" (Fig.31 Ref. 2) and the electronic
control panel to "ON". Once you have started up
the engine manually, put the selector switch back
to "0FF" (Fig.31 Ref. 2). The start-up battery
should never be disconnected, as there would be
no input to the electronic control panel which
would prevent the generating set from working.