Always fit a 100 A fuse
onto the positive cable connecting the
generating set to the positive pole of the
battery.

4.5 Electric Load connection

To connect loads to the power generating set,
use a three-pole cable up to the applicable
standards in force. The correct cross section is
shown in Table 1.
Table 1
Sect. mm
Model
line 230 V
4010B
4
LINE
CONNECTION 230 V
For connection to the 230V input line, the
generating set is equipped with a special terminal
strip (Fig.13 Ref.1) to which the cables must be
connected.
Vers. 001
2
Cable leng.
Cable leng
Lgth < 6 m
Lgth. > 6 m
10
16
BATTERY
CONNECTION
Energy 4010 B
GB
Use the special cable outlet (Fig.11 Ref.1) to
prevent water seeping into the generating set.
Although the generating set is equipped with a
special internal thermal cut-out to cut power
delivery in the event of overload or short circuits
(Fig.13 Ref.5), it is advisable to install (in the
vehicle control panel) a thermomagnetic cut-out
switch, suitably set to stop power delivery to the
various users when current absorption exceeds
16,5 Amp for ENERGY 4010 B
If the generating set thermal cut-out switch has
been operated, press the button (Fig. 7 Ref. 5) to
restore
closed
conditions.
position of the line connection for picking up
230 Volt current. Wrong connection could
damage the generating set irreparably or
create dangerous short circuits.
circuit
and
power
Carefully
check
delivery
the
11