Connectable Drive-Cliq Components - Siemens SINUMERIK ONE NCU 1740 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1740:
Table of Contents

Advertisement

Connecting
8.6 DRIVE-CLiQ components
PIN
8
A
B
Signal type: I = Input; O = Output; VO = Voltage Output
Position of the DRIVE-CLiQ interfaces
Figure 8-3
Cable specification
Table 8-6
Characteristic
Connector type
Cable type
Max. cable length
8.6.2

Connectable DRIVE-CLiQ components

Components
As a rule, all SINAMICS/SIMOTION components approved for SINUMERIK can be connected to an
NCU using DRIVE-CLiQ.
Table 8-7
Component
NX10.3 / 15.3
SINAMICS S120, system components, booksize format
66
Signal name
Signal type Meaning
-
-
+ (24 V)
VO
M (0 V)
VO
B
8
1
A
DRIVE-CLiQ interfaces
Cable specification for X100 - X103
Version
RJ45 socket
DRIVE-CLiQ standard (inside the control cabinet)
MOTION-CONNECT (outside the control cabinet)
70 m
Components with DRIVE-CLiQ
Description
Drive expansion module for up to 6 axes
Reserved, do not use
Voltage supply for DRIVE-CLiQ, 450 mA maximum
Ground to 24 V
Equipment Manual, 10/2021, A5E51087503B AA