Technical Data
Table 12-9
Protection class
Degree of protection to EN 60529
Approvals
Pollution degree
Cooling
Mounting position
PE/ground connection
Table 12-10
Input voltage
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current
Power loss
Dimensions WxHxD (with spacers)
Weight
12.2
PP 72/48D PN
12.2.1
Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting digital
input/outputs as part of an automation system based on PROFINET IO.
The module has the following important characteristics:
• PROFINET IO connection (max. 100 Mbits/s)
• 72 digital inputs and 48 digital outputs
• On-board status display via 2 diagnostic LEDs
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
Safety-related data
Electrical and mechanical data
Connectable components
III
IPXXB
CE, cULus
2
Open-circuit ventilation
Vertical
at the housing with M5 screw Torx / 3 Nm
24 V DC (20.4 – 28.8)
3.35 A
15 W
25 x 414 x 272 mm
2.58 kg
12.2 PP 72/48D PN