Siemens SINUMERIK ONE NCU 1740 Equipment Manual page 14

Hide thumbs Also See for SINUMERIK ONE NCU 1740:
Table of Contents

Advertisement

Fundamental safety instructions
2.1 General safety instructions
Electric shock due to equipment damage
Improper handling may cause damage to equipment. For damaged devices, hazardous
voltages can be present at the enclosure or at exposed components; if touched, this can result
in death or severe injury.
• Ensure compliance with the limit values specified in the technical data during transport,
• Do not use any damaged devices.
Electric shock due to unconnected cable shields
Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected
cable shields.
• As a minimum, connect cable shields and the cores of cables that are not used at one end
Electric shock if there is no ground connection
For missing or incorrectly implemented protective conductor connection for devices with
protection class I, high voltages can be present at open, exposed parts, which when touched,
can result in death or severe injury.
• Ground the device in compliance with the applicable regulations.
NOTICE
Damage to equipment due to unsuitable tightening tools.
Unsuitable tightening tools or fastening methods can damage the screws of the equipment.
• Be sure to only use screwdrivers which exactly match the heads of the screws.
• Tighten the screws with the torque specified in the technical documentation.
• Use a torque wrench or a mechanical precision nut runner with a dynamic torque sensor and
14
WARNING
storage and operation.
WARNING
at the grounded housing potential.
WARNING
speed limitation system.
Equipment Manual, 10/2021, A5E51087503B AA
NCU 1740

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik sinumerik one ncu 1740

Table of Contents