Stopping The Engine - K&S BASIC KSB 22i S Owner's Manual

Inverter generator
Hide thumbs Also See for KSB 22i S:
Table of Contents

Advertisement

"ON" MODE
"ON" MODE
When the ECONOMY MODE switch is in the "ON" position, the control unit monitors the engine speed, reducing it
commensurate with the connected load. If the engine speed is not enough to generate electricity to provide the load,
the control unit will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
"OFF" MODE
"OFF" MODE
The ECONOMY MODE switch must be set back to "OFF" when using electrical devices requiring a high starting current,
such as a compressor or submersible pump.
IMPORTANT!
PARALLEL FUNCTION
PARALLEL FUNCTION
You can increase the total output power of the generators by connecting the two inverter generators together with
special cables for parallel connection of KSB PC-1 from K&S Basic TM (not included in a set). Parallel connection of
two generators ensures total rated output power of these generators. When the generators are connected in parallel,
the power loss is 0.2 kW of the total rated power that can be obtained.
During parallel operation, the ECONOMY MODE switch must be in the same position on both generators.
1. Connect the KSB PC-1 parallel cable to the dedicated outputs on the generator control panel. Do not use any other
cables, don't combine different generator models.
2. Start the engines of the same generator models (KSB 22i S), check that the green WORKING MODE indicator on
each generator is on.
3. Plug the appliance into a socket.
4. Switch on the appliance.
If the overload indicator lights up, follow the standard generator overload procedure described in section 5 (reduce
the load and press the RESET button on both generators)
ATTENTION - DANGER!
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!
Do not stop the generator with the devices turned on. This may disable the generator or devices connected to it!
TO STOP THE ENGINE, PROCEED AS FOLLOWS:
TO STOP THE ENGINE, PROCEED AS FOLLOWS:
1. Turn off all devices.
2. Allow the generator to run idle for approx. 1-2 minutes.
3. Set the engine switch to the "OFF" position.
4. Set the 3-in-1 switch to "OFF" (Fig. 3).
5. Allow the generator to cool down.
6. Unplug the devices.
7. After the generator stops, allow it to cool down and
close the vent (set to OFF, as shown in Fig. 4).
The ECONOMY MODE switch must be set back to "OFF" when
using electrical devices requiring a high starting current, such as
a compressor or submersible pump.
Do not connect or disconnect parallel cables while the generator
is running. If you plan to use only one generator, the parallel
cables must be disconnected with the engine off.

STOPPING THE ENGINE

Fig. 3
www.ks-power.de/en
9
Fig. 4
| 7