E
NGINE START
NGINE START
IMPORTANT!
IMPORTANT!
1. Check oil level.
2. Check fuel level.
3. Open the vent on the fuel cap to the
"ON" position (Fig. 1).
4. Set the 3-in-1 switch to "Air choke"
(Fig. 2).
In this position:
Ignition circuit is on.
Fuel valve is open.
a.
b.
(If the engine is warm, no need to turn to Choke position, turn immediately to "ON" position).
5. Pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the
manual starter by hand, do not release it abruptly.
6. Set the 3-in-1 switch to "ON" (Fig. 2).
IMPORTANT!
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the
generator to run idle for 1-2 minutes so that it cools down.
ATTENTION – DANGER!
FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
ECONOMY MODE FUNCTION
ECONOMY MODE FUNCTION
1. Start the engine.
2. Set the ECONOMY MODE switch to "ON".
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
IMPORTANT!
Useful tip: If the engine stalls or does not start, turn the engine
switch to the "ON" position, and then pull the manual starter. If
the oil level indicator flickers for several sECONOMY MODEds, add
oil and restart the engine.
Each time you start the generator, be sure to check oil and fuel
level
Air choke is closed.
c.
Useful tip: to ensure long-term operation of the generator
engine, it is important to observe the following tips:
Do not connect two or more devices at a time. The start-
up of many devices requires high power. Devices should be
connected one at a time according to their power rating.
Do not connect any power consumers within the first
2 minutes after the generator has been started.
The ECONOMY MODE switch must be set to "OFF" to increase
engine speed to nominal. When connecting multiple power
consumers to the generator, be sure to first connect the one
with the highest starting current, and the device with the
lowest starting current should be connected last.
Fig. 1
www.ks-power.de/en
Fig. 2
8