9

Warning and Status Messages

Warning and status messages can be set or changed at any time with the KESO Management
Software (see Item 4). The messages are set as follows as a factory default:
Function
Buzzer
LED Signaling
Flat battery signaling
Always open signaling
Indicate latch in place
Opening duration on access
9.1
Access permitted
Default setting:
If access is permitted an audible signal is emitted and the green
LED flashes
9.2
Access denied
Default setting:
If access is denied an audible signal is emitted and the red
LED flashes
9.3
Always open
Default setting:
If always open is set (e.g. via a time slot for a PC Time
Version) the green LED flashes periodically
9.4
Status change for office function
The switch from always open to always closed state is indicated by the red and
green LEDs flashing twice simultaneously.
9.5
Low battery power
Low battery power is indicated by a multiple stage warning message (optical and
acoustic).
KESO recommends checking the battery capacity once a year!
KESO AG
Default
Comment
status
ON
OFF
Extends the battery life
ON
OFF
Extends the battery life
ON
OFF
Extends the battery life
ON
OFF
Extends the battery life
ON
OFF
Extends the battery life
5 sec
Range 5 to 30 seconds