Quick Start Guide B1100-VF
Set the input on X14.2 low to complete the homing.
By setting the input on X14.3 the current command interface will be activated!
Before activating the superior position control loop, make sure the position
control loop in your superior system is initialised correctly and the position
feedback direction is correct! Otherwise the motor will accelerate in any
direction and crash to a limit!
If an error occurs, the output on X14.6 will go high. It can be acknowledged by a rising edge on
the input X14.15.
NTI AG, LinMot
Quick Start Guide E1100-VF 06.12.2007
Page 15/16