Sharp PN-80TH5 Operation Manual page 53

Hide thumbs Also See for PN-80TH5:
Table of Contents

Advertisement

Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
SIGNAL RESPONSE LEVEL
Others
Function
SIZE (Screen size selection)
INFORMATION
Model
Serial no.
Temperature sensor
Temperature acquisition
Cause of last standby mode
Touch operation valid/invalid
FREEZE
Commands for setting of the GAMMA user data
Function
Red gamma data transfer
Green gamma data transfer
Blue gamma data transfer
Red gamma data read
Green gamma data read
Blue gamma data read
User data initialize
User data save
Controlling the Monitor with a computer (RS-232C)
Command
Direction
Parameter
RSET
W
0-1
ALCK
WR
0-2
ALTG
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
PBTN
WR
0-1
PCIP
WR
0-3, 5, 6
HDUC
WR
1-200
Command
Direction
Parameter
WIDE
WR
1-5
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
TPEN
WR
0-1
FRMD
WR
0-1
Command
Direction
Parameter
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
UGGW
W
aa: 01-16
UGBW
W
xxxx: 0000-1023
cc: 00-FF
UGRR
W
1-16 xxxx ··· xxxx
UGGR
W
1-16
UGBR
W
1-16
UGRS
W
0
UGSV
W
0
Reply
0: ALL RESET 1, 1: ALL RESET 2
0-2 0: OFF, 1:ON 1, 2:ON 2
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
0-2 0: ON 1, 1: OFF, 2: ON 2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
0-1 0: MONITOR, 1: EXT. CONTROLLER
0-3, 5, 6 0: D-SUB, 1: DisplayPort1, 2: HDMI1, 3: HDMI2, 5: HDMI3, 6: DisplayPort2
("ERR" when MONITOR is selected for POWER BUTTON.)
1-200
Reply
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
9 Standby mode by DDC/CI
10 Standby mode by HDMI CEC
20 Standby mode by OFF IF NO OPERATION setting
0-1 0: Invalid, 1: Valid
"ERR" when TOUCH INPUT SELECT is set to INVALID or the touch panel is not
connected.
0-1 0: FREEZE release, 1: FREEZE execute
Reply
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
Initialize the user data.
Save the user data in the monitor.
Control/Response contents
Control/Response contents
Control/Response contents
*
-
*
-
*
53
E

Advertisement

Table of Contents
loading

Table of Contents