1-3. Setting the Room temperature sensor switching (Only for Wired remote controller)
When using the Wired remote controller temperature sensor , change the setting to "Both" (01).
Function Number
42
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
Remote controller sensor must be turned on by using the remote controller.
1-4. Setting the Remote controller custom code (Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
Function Number
44
1-5. Setting the External input control
"Operation / Stop" mode or "Forced stop" mode can be selected.
Function Number
46
1-6. Setting the Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only,
change the setting to "Wired remote controller" (01).
This function will only work if the function setting 42 is set at "Both" (01)
When the setting value is set to "Both"(00),more suitable control of the room temperature
by setting function setting 30 and 31 too.
Function Number
48
(
Setting Value
Setting Description
00
01
(
Setting Value
Setting Description
00
01
02
03
(
Setting Value
Setting Description
00
Operation / Stop mode 1
01
(Setting prohibited)
02
Forced stop mode
03
Operation / Stop mode 2
(
Setting Value
Setting Description
00
01
Wired remote controller
03-02
Factory setting)
Indoor unit
Both
Factory setting)
A
B
C
D
Factory setting)