Fujitsu ASU30RLE Service Instruction page 63

Split type room air conditioner
Hide thumbs Also See for ASU30RLE:
Table of Contents

Advertisement

Trouble shooting 24
OUTDOOR UNIT Error Method:
Current Sensor Error
Detective Actuators:
Outdoor unit main PCB
Forecast of Cause:
1. Defective connection of electric components 2. External cause 3. Filter PCB failure 4. Main PCB failure
Test 1-1 : Reset Power Supply and operate
Does Error indication show again?
YES
Test 2 : Check connections of Outdoor unit electrical
components
Check if
the terminal connection
Check if connector is removed.
Check erroneous connection.
Check if cable is open.
>>Upon correcting the removed connector or
miss-wiring, reset the power.
OK
Test 3 : Replace Filter PCB
If Test 1, 2 do not improve the symptom, change Filter PCB.
OK
Test 4 : Replace Main PCB
If Test 3 do not improve the symptom, change Main PCB.
Indicate of Display:
Indoor Unit :
Operation lamp: 8 times Flash,
Timer lamp
ERROR CODE : [E : 84]
Detective details:
When input Current Sensor has detected 0A, while inverter compressor is
operating at higher than 50Hz. after 1 minute upon starting the compressor
(Except during the defrost operation)
is loose.
Outdoor unit :
POWER
MODE
: 4 times Flash
NO
Test 1-2 : Check external cause at Indoor and Outdoor
(Voltage drop or Noise)
Instant drop : Check if there is a large load electric
apparatus in the same circuit.
Momentary power failure : Check if there is a defective
Noise : Check if there is any equipment causing
harmonic wave near electric line.(Neon bulb or
electric equipment that may cause harmonic wave)
Check the complete insulation of grounding.
02-27
PUMP
LOW
DOWN
NOISE
ERROR
(L1)
(L2)
(L3)
(L4)
8
4
2
: Light OFF
: Light ON
n : n times blinking
c
o
n
a t
t c
r o
e l
a
k
c
r u
e r
t n
p
o
w
r e
s
u
p
p
y l
i c
c r
u
. t i
PEAK
CUT
(L5)
(L6)
n i
h t
e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou30rlxeh

Table of Contents