Forced Cooling Operation; Heat Insulation Condition (When Using The Wireless Rc); Thermo Control (For Indoor Unit Sensor); Thermo Control (For Wired Remote Sensor) - Fujitsu ASU30RLE Service Instruction

Split type room air conditioner
Hide thumbs Also See for ASU30RLE:
Table of Contents

Advertisement

1-25. FORCED COOLING OPERATION ( When using the Wireless RC )
The FORCED COOLING OPERATION starts up when MANUAL / AUTO button is pressed more than 10 seconds.
During the FORCED COOLING OPERATION, it keeps operation regardless of detection
value of room temperature sensor.
Operation LED and Timer LED blinks simultaneously while the unit is on the FORCED COOLING OPERATION.
It is released after 60 minutes from starting time.
1-26. HEAT INSULATION CONDITION ( BUILDING INSULATION )
This setting can make the room temperature control more suitable for homes or buildings
with high insulation (Function Number 95).
When the thermo sensor is turned ON it controls the compressor frequency at
initial start to prevent overshoot in heating or cooling.
1-27. THERMO CONTROL ( FOR INDOOR UNIT SENSOR )
When room temperature is controlled by the Indoor unit sensor, compressor operation
is as shown in Fig. 14 and 15 .
But, adjustment is possible by the room temperature correction function setting.
(Function Number 30 or 31)
( Fig. 14 : For cooling operation )
Compressor ON
Ts - 1°F
(Ts - 0.5°C)
Compressor OFF
Ts : Setting temperature
1-28. THERMO CONTROL ( FOR WIRED REMOTE SENSOR )
When room temperature is controlled by the Wired remote sensor, compressor
operation is as shown in Fig. 16 and 17 .
But, adjustment is possible by the room temperature correction function setting.
(Function Number 92 or 93)
( Fig. 16 : For cooling operation )
Ts - 1°F
(Ts - 0.5°C)
Ts : Setting temperature
Ts + 1°F
(Ts + 0.5°C)
Compressor ON
Compressor OFF
( Fig. 15 : For heating operation )
Ts + 1°F
(Ts + 0.5°C)
( Fig. 17 : For heating operation )
Ts + 1°F
Ts
(Ts + 0.5°C)
01-19
Compressor OFF
Compressor ON
Compressor OFF
Compressor ON
Ts - 1°F
(Ts - 0.5°C)
Ts

Advertisement