Beretta MYNUTE X R Installer And User Manual page 21

Hide thumbs Also See for MYNUTE X R:
Table of Contents

Advertisement

Available languages

Available languages

Boiler faults list
ERROR
ERROR MESSAGE
CODE
E010
flame lockout/ACF electronic fault
E011
extraneous flame
E020
limit thermostat
E030
fan fault
E040
water transducer - load the system
E041
water transducer - load the system
E042
water pressure transducer fault
E060
storage tank probe fault
fault flow sensor/overtemperature flow sensor/
E070
flow/return sensor differential alarm
E077
main zone water thermostat or zone 1 (when enabled)
fault return line probe/return line probe overtemperature/
E080
outlet/return line probe differential alarm
E084
delivery line probe fault - zone 1
E086
delivery line probe fault - main zone
fault flue gases probe/
E090
flue gases overtemperature probe
E091
clean primary heat exchanger
E099
reset attempts exhausted, boiler blocked
<0,6 bar
low pressure - check the system
>3,0 bar
high pressure - check the system
COM
lost communication with boiler board
COMP
lost communication with main zone
COM1
lost communication with zone 1
FWER
FW version not compatible
OBCD
damaged clock
OTER
OTBus configuration fault
List of combustion faults
ERROR CODE
ERROR MESSAGE
E021
E022
E023
E024
E067
E088
E097
E085
incomplete combustion
E094
incomplete combustion
E095
incomplete combustion
E058
E065
current modulation alarm
E086
obstruction fumes alarm
Warning lights
BOILER STATUS
Power-on
Vent cycle
flashing 0.5 sec. on/1 sec. off
OFF status
No heat request (stby)
Transitional ignition/
overtemperature
Presence of flame
Chimney sweep
Screed heater
flashing 1 sec. on/1 sec. off
flashing 0.2 sec. on/0.2 off
flashing 0.5 sec. on/0.5 off
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
mains voltage fault
RED LED
flashing 0.5 sec. on/1 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 1 sec. on/1 sec. off
RED LED
GREEN LED
ON
ON
flashing 0.5 sec. on/0.5 off
ON
ON
ON
flashing 0.5 sec. on/3.5 off
flashing 0.5 sec. on/3.5 off
It is referred to the last fault occurred
flashing 0,5 sec. ON/
0,5 sec. OFF
flashing 0,5 sec. ON/
0,5 sec. OFF
ON
flashing 0.5 sec. on/3.5 off
flashing 0.5 sec. on/3.5 off
flashing 0.5 sec. on/3.5 off
flashing 0,5 sec. ON/
0,5 sec. OFF
flashing 0.5 sec. on/3.5 off
LED
LED
RED
GREEN
ON
ON
These are temporary alarms that if they occur 6 times in an hour they become definitive;
ON
the alarm E097 is displayed and is followed by post-purging for 45 seconds at the fan's
ON
maximum speed. It is not possible to release the alarm before the end of the post-purging
ON
unless the boiler's power supply is switched off.
ON
ON
ON
These are temporary alarms that if they occur several times in an hour they become de-
finitive; the last error to occur is displayed and is followed by a post-purging of 5 minutes
ON
at the fan's maximum speed. It is not possible to release the alarm before the end of the
ON
ON
ON
Temporary fault reported during the post ventilation. It is maintained a post ventilation of 5
ON
GREEN LED
RED and GREEN
flashing 0.5 sec. on/0.5 sec. off
ON
ON
RED and GREEN
ON
ON
flashing 0.5 sec. on/0.5 off
flashing 0.5 sec. on/0.5 off
flashing 0.5 sec. on/0.5 off
DESCRIPTION OF TYPE OF ALARM
post-purging unless the boiler's power supply is switched off.
These are temporary faults that restrict the ignition cycle.
min at maximum fan speed.
NOTES
The red and green LEDs come on at the same time
The red and green LEDs come sequentially one at a time
Only if the flame is present
The red and green LEDs come on alternately
ENGLISH
DESCRIPTION OF TYPE
OF ALARM
definitive
transitional
definitive
definitive
definitive
transitional
definitive
transitional
transitional/definitive/
definitive
transitional
transitional/definitive/
definitive
transitional
transitional
transitional
definitive
transitional
definitive, not resettable
signalisation
signalisation
transitional
transitional
transitional
definitive
signalisation