Drs-10 Led Status; Mechanically Arming The Drs-10 - Innoflight GALAXY 950 Operating Manual

Table of Contents

Advertisement

Page
| 38
the compass calibration process view page .28 of this manual. To test the automatic
activation, enter the compass calibration protocol, when the vertical calibration is
conducted the Galaxy will rotate past 90degrees activating the DRS-10. A red LED and
audible alarm will be observed. To replace the weight of the silk being removed it is
recommended to use a weighted object to avoid damaging the carbon fibre structure of the
DRS-10. A simple filled water bottle installed in place of the parachute silk will simulate this.

DRS-10 LED Status

The DRS-10 utilises an external LED used to indicate the system status.

Mechanically Arming the DRS-10

With the Galaxy 950 de-powered, use your finger to lift the white locking arm located on the
outside of the DRS-10. Using the water bottle or a tube that fits inside the DRS-10 push the
carbon fibre plate all the way into the DRS-10, you will feel the tension of the rubber tighten
as the plate reaches the end of its travel. There is a locking shaft that must go all the way
into the firing mechanism. Once you have pushed the plate all the way to the end of its
travel, release the white latch to lock the plate in place. You can confirm that the system is
securely locked in place by removing the water bottle/tube used to push the plate in.
| Version 1.5