List of all supported CVs
CV
Name
43
Pulse configuration
44
Function Mapping
„F1"
45
Function Mapping
„F2"
46
Function Mapping
„F3"
47
Function Mapping
„F4"
48
Function Mapping
„F5"
34
Description
Options for generating the servo pulses. This applies equally to all outputs.
Bit
Description
0
Always generate a servo pulse
Generate servo impulse only after the first command
1
Never switch off the servo pulse
Switch off the servo pulse approx. 1 second after reaching the end position
2
Always supply power to the servo
Only supply the servo with power when it is to be moved
Servos that switch at turnout number 1.
Bit
Description
0
Servo 1
1
Servo 2
2
Servo 3
3
Servo 4
4
Servo 5
5
Servo 6
6
Servo 7
7
Servo 8
Servos that switch at turnout number 2.
Bit
Description
- as CV 44 -
Servos that switch at turnout number 3.
Bit
Description
- as CV 44 -
Servos that switch at turnout number 4.
Bit
Description
- as CV 44 -
Servos that switch at turnout number 5.
Bit
Description
- as CV 44 -
Range
Value
0 - 7
0
Value
1
2
4
0 - 255
1
Value
1
2
4
8
16
32
64
128
0 - 255
2
Value
0 - 255
4
Value
0 - 255
8
Value
0 - 255
16
Value