SAMES KREMLIN 3000 User Manual page 45

Pneumatic motor
Table of Contents

Advertisement

Standard cabling
Direct piloting
Rexson-Dispense-pneumatic-motor-3000-instructions-manual-sames-kremlin-582140110-EN.docx
All factory assembled motors are wired in standard control. This means
that the pneumatic motor reversing system (called pilot) is connect ed
to the same pressure as the main motor supply. In this case, the starting
threshold of the motor is approximately 21.7 psi. (1,5 bar).
Direct piloting allows the user to connect the pneumatic motor
reversing system (called pilot) to an independent pressure source. This
allows the user to start the motor at a supply pressure of approximately
7.25 psi (0.5 bar) or to use the pilot pressure to control the starting and
stopping of the motor.
22/07/2021
Pneumatic cabling
45