12 Disassembly / Reassembly Operation
12.1 Disassembling the 3000 motor
Disassembly of the
grounding cable
Tools needed
Rexson-Dispense-pneumatic-motor-3000-instructions-manual-sames-kremlin-582140110-EN.docx
Before any intervention, it is imperative to follow the
decompression procedure and the safety instructions.
The maintenance consists in changing the damaged parts and
cleaning the parts with compatible materials without using abrasive
materials which can damage them. The O-Rings are mounted with a
'special pneumatic' grease. Make sure during the assembly that the
seals are not damaged to avoid a bad operating of the motor.
Hold the grounding terminal with a 10 mm spanner and
unscrew the upper nut with the other key.
Manually remove the washers and the grounding cable.
Disassembly / Reassembly Operation
Attention
10 x2
22/07/2021
39