4
Splice the input of the splitter to the feeder fiber (entering directly on the rear tray) by making a fusion splice: make
fusion splice per standard practice, store the splice protector in the splice protector holder and store over length in
loops on the tray.
5
If the feeder fibers come from the uncut storage zone, one of the fibers should be routed through the channel in
the middle of the tray before to store over length in loops on the tray.
Important:
Make sure all fibers are properly positioned under the lips and avoid bulging of the fiber
Note:
The fiber guidance pen (situated on top of the loop storage basket) can be used to position all the fibers
under the lips.
6
Splice the output of the splitter to the connector input. For the SC application, store all 6 splice protectors in the
splice protector holder and store over length.
Note:
Note that for the LC application, to connect all 12 drops, an extra splice protector holder should be installed
in position 4.
5

Pre-connectorized cable

5.1

Install SC-connectorized cable

1
1
Remove dust caps of the adapter port. Clean per standard practice.
2
Remove dust caps of the connector. Clean the connector per standard practice.
3
Position the connector in the correct orientation (rib facing forward as shown in figure above).
2
page 6 / 13
© 2021 CommScope, Inc. All Rights Reserved
3