4
4
Coil the transition length and store it in loops in the organizer, under the lips and under the connectors. Make sure
not to store transition length in the area where the remaining carriers will be installed.
Important:
Make sure the transition lengths are properly positioned under the lips and avoid bulging.
Important:
Make sure to respect the minimum bend radius when storing the transition lengths.
Note:
The fiber guidance pen (situated on top of the loop storage basket) can be used to position all the transition
lengths under the lips.
5
Transition length stored of cables installed in position 1-3.
6
Transition length stored of cables installed in position 1-6.
6.2

Install LC-connectorized cable with transition and FIC

The separate cable retention kit TC-1467-IP (Cable retention: Dual cable ) must be used to install the LC-connectorized
cable with transition in the CC 100 patch application.
1
1
If applicable, install the FIC per local practice. Follow the installation steps as described in TC-1467-IP to mount the
cables on the carrier. Slide the carrier into the slots of the organizer. Push the locking lip in the first slot backwards
then slide the carrier downwards. The locking lip returns into original position and the carrier is correctly seated. A
clicking sound is observed.
2
Remove dust caps of both connector and adapter of the selected port. Clean the connector and adapter per
standard practice. Position the connector in the correct orientation (clip facing forward as shown in figure above).