Body Ported
Plug Lead Unit: Flip Type
Series
2
VQ2000
Simple specials are available with
SMC Simple Specials System. For
details about applicable models,
please contact SMC.
Kit/Electrical entry/Cable length
F
kit
(D-sub connector)
Note 1)
25P
Side entry
Connector entry direction
Top entry
Side entry
U0
S0
U1
S1
U2
S2
U3
S3
T
kit
(Terminal block)
1
No. of terminals: 8, 1 row
Applicable stations 1 to 8
Kit
T
2
No. of terminals: 16, 2 rows
Applicable stations 5 to 16
Note 1)
Besides the above, F and P kits with different number of pins are available. For details, refer to page 2-4-68.
Note 2)
See page 2-4-69 for details.
Note 3)
Please consult with SMC for the following serial transmission kits: Matsushita Electric Works, Ltd.; Rockwell Automation, Inc.; SUNX Corporation; Fuji
Electric Co., Ltd.; OMRON Corporation.
2-4-34
VQ2000
How to Order Manifold
VV5Q
2 4
Manifold
4
Plug lead unit/Flip
Stations
01
1 station
The number of max. stations
differs from kit to kit.
(Refer to the table below.)
Note 1)
25P
Top entry
P. 2-4-38
Without cable
With cable (1.5 m)
Max. 16
stations
With cable (3 m)
With cable (5 m)
C
kit
(Connector)
P. 2-4-46
C
08
F
S1
D
Nil
D
K
N
(4)
S
P
kit
(Flat ribbon cable connector)
Note 1)
26P
Connector entry direction
Top entry
Side entry
U0
S0
(2)
U1
S1
U2
S2
U3
S3
P. 2-4-50
Connector kit
Max. 16
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Option
None (C kit only)
(2)
DIN rail mounting style
(3)
Special wiring specifications (Except double wiring)
With name plate
Built-in silencer, direct exhaust
Note 1)
When two or more symbols are specified,
indicate them alphabetically. Example) -DNS
Note 2)
F, P, T, and S kits are of DIN rail include
suffix -D
Note 3)
Specify the wiring specifications in the
manifold specification sheet. (Except C kit)
Note 4)
F, P, T and S kits are provided with an
exhaust on one side, while C kits are with an
exhaust on both sides.
Note 1)
26P
Side entry
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
S
kit
(Serial transmission unit)
The dust-protected type
SI unit is applicable, too.
For
contact SMC.
0
Without SI unit
A
With general type SI unit (Series EX300)
B
Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System
C
OMRON Corp.: SYSBUS Wire System
D
SHARP Corp.: Satellite I/O Link System
F1
NKE Corp.: Uni-wire System (16 output points)
H
NKE Corp.: Uni-wire H System
Top entry
P. 2-4-42
(2)
Max. 16
stations
The valve is equipped
with
an
indicator
light/surge
voltage
suppressor and the
voltage is 24 VDC.
details,
please
P. 2-4-54
(2)
Max. 16
stations

Advertisement

loading

Summary of Contents for SMC Networks VQ2000 Series

  • Page 1 For details about certified products conforming to international standards, visit us at www.smcworld.com. VQ2000 Series Body Ported Plug Lead Unit: Flip Type How to Order Manifold VV5Q Series Option VQ2000 Manifold None (C kit only) Plug lead unit/Flip DIN rail mounting style Special wiring specifications (Except double wiring) With name plate Stations...
  • Page 2 Body Ported VQ2000 Series Plug Lead Unit: Flip Type How to Order Valves 2 1 4 0 Y Cylinder port Symbol Port size Series With One-touch fitting for ø4 VQ2000 With One-touch fitting for ø6 Electrical entry With One-touch fitting for ø8 Type of actuation Coil voltage Note)
  • Page 3 Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type Manifold Specifications Porting specifications Applicable 5 station Applicable Port size Series Base model Type of connection solenoid weight stations Port location valve 1(P), 3(R) 4(A), 2(B) í F kit–D-sub connector C6 (ø6) C3 (ø3.2) í...
  • Page 4 VQ0000/1000/2000 Kit (Flat ribbon cable connector) VV5Q04 VV5Q14 VV5Q24 Manifold Specifications MIL flat ribbon cable connector reduces installation labor savings for Porting specifications electrical connection. Applicable Series Port size Port Using the connector for flat ribbon cable (26P), (10P, 16P, 20P as an stations location 1(P), 3(R)
  • Page 5 Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type VQ2000 55.5 (M plug connector AC, Latching) 50.5 (M plug connector) Indicator light (L plug connector AC, Latching) Flat ribbon cable unit mounting screw Manual override (L plug connector) DIN rail clamp screw Applicable connector: Flat ribbon cable (26P) (Conforming to MIL-C-83503)
  • Page 6 Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type Manifold Option Parts for VQ2000 Blanking plate assembly VVQ2000-10A-4 It is used when a blanking plate is mounted to amanifold in advance for possible valve mounting, etc. Note) P block valve Individual SUP spacer (To be ordered using Individual SUP...
  • Page 7 Body Ported VQ0000/1000/2000 Series Manifold Option Parts for VQ2000 ∗ When ordering assemblies incorporated with Name plate [-N4] a manifold, add suffix N to the manifold no. VVQ2000-N4-Station (1 to Max. stations) It is a transparent resin plate for placing a label that Indicates solenoid valve function, etc.
  • Page 8: Specifications

    Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type Manifold Option Double check block (Separated type) <Check valve operation principle> „„ „ VQ2000-FPG- It is used on the outlet side piping. Combining the double check block with built-in pilot double check valve and a two-position single/double solenoid valve will prevent Cylinder side the dropping at the cylinder stroke end when the SUP residual...
  • Page 9 Body Ported VQ0000/1000/2000 Series Precautions Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 2-9-2. Light/Surge Voltage Suppressor How to Mount/Remove Solenoid Valve Tie-rod bolt A Caution Caution Light cover The lighting positions are concentrated on one side for both single <Procedure>...
  • Page 10 Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type Replacement of Cylinder Port Fittings Built-in Silencer Replacement Element Caution Caution Clip The cylinder port fittings are a A silencer element is incorporated in the end plate on both sides of cassette for easy replacement.
  • Page 11 Body Ported VQ0000/1000/2000 Series Option Different Number of Connector Pins F and P kits with the following number of pins are available. Besides the standard number (F = 25; P = 26) select the desired number of pins and cable length from the cable assembly list. Place an order for the cable assembly separately. kit (Flat ribbon cable connector) kit (D-sub connector) 15 pins 10 pins, 16 pins, 20 pins...
  • Page 12 Body Ported VQ0000/1000/2000 Series Plug Lead Unit: Flip Type Special Wiring Specifications Inch-size One-touch Fittings Refer to following model no. for inch-size One-touch fittings. In the internal wiring of F kit, P kit, T kit and S kit, double wiring (connected to SOL.
  • Page 13: Din Rail Mounting

    Body Ported VQ0000/1000/2000 Series Option DIN Rail Mounting Each manifold can be mounted on a DIN rail. Order it by indicating an option symbol for DIN rail mounting style, -D. In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached.
  • Page 14 Series VQ2000 (VV5Q24)/Plug Lead Unit, Flip Type (F, P, T, S kit) ∗ For how to increase the stations, refer to the instruction manual. Station Housing assembly and SI unit U side end plate assembly Valve D side end plate assembly increase parts Note 2) Connector...
  • Page 15 Series Exploded View of Manifold <Housing Assembly and SI Unit> Housing assembly and SI unit no. Manifold Part no. Description EX330-S001 (SA kit) General type SI unit (Series EX300) EX130-SMB1 (SB kit) SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric Corporation) (SC kit) EX130-STA1 SI unit for SYSBUS Wire System (OMRON Corporation)