Download Print this page

SMC Networks 55 Series Instruction Manual

Compact cylinder iso standard

Advertisement

Quick Links

55-C55*-SMX55EN
ORIGINAL INSTRUCTIONS
Refer to Declaration of
Conformity for relevant
Instruction Manual
Directives
Compact Cylinder ISO Standard
55-C55 Series
Ex h IIC T6/T4 Gb
-10°C ≤ Ta ≤ 60°C
II 2 GD
Ex h IIIC T84°C/T104°C Db
Product marking shown above is for the standard product.
ATEX Marking Description:
Specific Marking for Explosion Protection
II
Equipment Group
2
Equipment Category
GD
Environment (Gas/Dust)
Ex h
General Protection Level Symbols
IIC
Gas Sub-Division
IIIC
Dust Sub-Division
T
Temp. Classification
Gb/Db
Equipment Protection Level
X
Special Conditions of Use
Ta
Ambient Temperature Range
The intended use of an actuator is to convert the potential energy
provided by compressed air into a force which causes mechanical linear
motion.
Certifcate Number:
SMC19.0031 X
Note 1: The X at the end of the certificate number represents that this
product is subject to "Special Conditions of Use", please see Section 2.3.
1 Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage. These instructions indicate the level of
potential hazard with the labels of "Caution," "Warning" or "Danger."
They are all important notes for safety and must be followed in addition
*1)
to International Standards (ISO/IEC)
, and other safety regulations.
*1)
ISO 4414: Pneumatic fluid power - General rules relating to systems.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots -Safety. etc.
• Refer to product catalogue, Operation Manual and Handling
Precautions for SMC Products for additional information.
• Keep this manual in a safe place for future reference.
Caution indicates a hazard with a low level of risk which, if
Caution
not avoided, could result in minor or moderate injury.
Warning indicates a hazard with a medium level of risk
Warning
which, if not avoided, could result in death or serious injury.
Danger indicates a hazard with a high level of risk which, if
Danger
not avoided, will result in death or serious injury.
Warning
• Always ensure compliance with relevant safety laws and
standards.
• All work must be carried out in a safe manner by a qualified person in
compliance with applicable national regulations.
2 Specifications
This product is certified to ATEX Category 2GD and therefore is
suitable for use in Zones 1, 2, 21 and 22 only.
2.1 Product Specifications:
Refer to the operation manual for this product;
2.1.1 Standard Product:
Fluid
Air
Max. Operating Pressure
1.0 MPa
Min. Operating Pressure
0.05 MPa
Ambient & Fluid Temperature
-10°C to +60°C
Lubrication
Not Required
Operating Piston Speed
Ø20~Ø63
50 to 500 mm/s
Ø80~Ø100
50 to 300 mm/s
Cushion
Rubber Bumper
Ø 20
0.110 J
Ø 25
0.180 J
Ø 32
0.290 J
Ø 40
0.520 J
Allowable Kinetic Energy
Ø 50
0.910 J
Ø 63
1.540 J
Ø 80
2.710 J
Ø 100
4.540 J
2.2 Production Batch Code:
The batch code printed on the label indicates the month and the year of
production as per the following table;
Production Batch Codes
...
Year
2017
2018
2019
2021
2022
2023
Month
...
V
W
X
Z
A
B
...
Jan
O
Vo
Wo
Xo
Zo
Ao
Bo
...
Feb
P
VP
WP
XP
ZP
AP
BP
...
Mar
Q
VQ
WQ
XQ
ZQ
AQ
BQ
...
Apr
R
VR
WR
XR
ZR
AR
BR
...
May
S
VS
WS
XS
ZS
AS
BS
...
Jun
T
VT
WT
XT
ZT
AT
BT
...
Jul
U
VU
WU
XU
ZU
AU
BU
...
Aug
V
VV
WV
XV
ZV
AV
BV
...
Sep
W
VW
WW
XW
ZW
AW
BW
...
Oct
X
VX
WX
XX
ZX
AX
BX
...
Nov
Y
Vy
Wy
Xy
Zy
Ay
By
...
Dec
Z
VZ
WZ
XZ
ZZ
AZ
BZ
2.3 Special Conditions of Use:
• Products are suitable for sub-divisions IIC & IIIC.
• Products are suitable for Zones 1, 2, 21 & 22 only.
2.3.1 Temperature Marking:
2.3.1.1 Standard Product:
• In the normal ambient temperature range (-10°C to +40°C) the product
is rated to temperature class T6 and has a maximum surface
temperature of 84°C.
• In the special ambient temperature range (+40°C to +60°C) the product
is rated to temperature class T4 and has a maximum surface
temperature of 104°C.
3 Installation
3.1 Installation
Warning
• Do not install the product unless the safety instructions have been read
and understood.
• Do not twist or bend the cylinder, or mount the product when subject
to tension.
• Do not use in an application where the product is stopped mid-stroke,
via an external stop.
• Do not use where cylinders are being synchronised to move a single
load.
• In order to install the product, use one of the brackets available found
in the standard product catalogue;
Mounting
Mounting
Bracket
Sketch
Bracket
[Part Number]
[Part Number]
Foot Brackets
Single Clevis
[C55-Lxxx]
[C55-Cxxx]
Rod Side Flange
Head Side Flange
[C55-Fxxx]
[C55-Fxxx]
Note 2: The "xxx" represents the Bore Size (e.g. Ø40 is 040), see catalogue for
more details.
• When replacing brackets use the hexagon wrench and torques shown
below;
Width Across
Bore [mm]
Bolts
Flats [mm]
Ø 20 & Ø 25
CQ-M4x*L
4
Ø 32 & Ø 40
CQ-M5x*L
4
Ø 50 & Ø 63
CQ-M6x*L
5
Ø 80 & Ø 100
CQ-M8x*L
6
Note 3: "*" is dependent on the stroke of the product, see catalogue for details.
3.2 Environment
Warning
• Do not use in an environment where corrosive gases, chemicals,
water, salt water or steam are present.
• Do not use in an explosive atmosphere except within the specified
rating.
• Do not expose to direct sunlight. Use a suitable protective cover.
• Do not install in a location subject to vibration or impact in excess of
the product's specifications.
• Do not use in a place subject to heavy vibration and/or shock.
• Do not use in wet environments, where water can remove the presence
of the lubrication.
...
• Do not use in case of heavy dusty environments where dust can
...
penetrate into the cylinder and dry the grease.
...
• Do not allow dust layers to build up on the cylinder surface and insulate
...
...
the product.
...
...
3.3 Piping
...
Caution
...
...
• Before connecting piping make sure to clean up chips, cutting oil, dust
...
etc.
...
• When installing piping or fittings, ensure sealant material does not
...
enter inside the port. When using seal tape, leave 1 thread exposed
...
on the end of the pipe/fitting.
• Tighten fittings to the specified tightening torque.
Model
Port Size
Model
Ø 20 & Ø 25
M5 x0.8
Ø 32 ~ Ø 100
3.4 Lubrication
Caution
• SMC products have been lubricated for life at manufacture, and do not
require lubrication in service.
• If a lubricant is used in the system, refer to catalogue for details.
3.5 Basic Circuit
Sketch
• Plugging one of the ports on the actuator is considered a non-intended
use, and could relate to an increase in maximum surface temperature
above what the product specification declares.
3.6 Electrical Connection
• The product should be grounded by the piston rod and the body in
order
to
create
an
electrically
system/application.
Tightening
• Ground the product in accordance with applicable regulations.
Torque [N.m]
3.0 ~ 5.4
• Do not pass an electrical current through the
9.0 ~ 12.0
11.4 ~ 22.4
25.0 ~ 44.9
4 Settings
• Refer to the operation manual of the C55 series products.
5 How to Order
Refer to the standard product catalogue for 'How to Order'.
6 Outline Dimensions (mm)
Refer to the standard product catalogue for general dimensions.
7 Maintenance
7.1 General Maintenance
Caution
• Not following proper maintenance procedures could cause the product
to malfunction and lead to equipment damage.
• If handled improperly, compressed air can be dangerous.
• Maintenance of pneumatic systems should be performed only by
qualified personnel.
• Before performing maintenance, turn off the power supply and be sure
to cut off the supply pressure. Confirm that the air is released to
atmosphere.
• After installation and maintenance, apply operating pressure and
power to the equipment and perform appropriate functional and
leakage tests to make sure the equipment is installed correctly.
• If any electrical connections are disturbed during maintenance, ensure
they are reconnected correctly and safety checks are carried out as
required to ensure continued compliance with applicable national
regulations.
• Do not make any modification to the product.
• Do not disassemble the product, unless required by installation or
maintenance instructions.
• Do not use a product which looks or contains damage, this will
invalidate the certification. If damage is seen, please replace the
product immediately.
• Periodically check the product for any damage or rust appearing. This
could result in an increase in friction and lead to dangerous conditions.
Replace the whole actuator if any of these conditions appear.
• Periodically check the condition of the rod seal and for the presence of
lubrication, where possible. If these areas appear to be dry, please
Port Size
follow the lubrication procedure.
G 1/8
• Replace the seals, when air leakage is above the allowable value given
in the table below;
Internal Leakage
External Leakage
conductive
path
to
the
product.
Allowable Leakage
3
10 cm
/ min (ANR)
3
5 cm
/ min (ANR)
Page 1 of 2

Advertisement

loading

Summary of Contents for SMC Networks 55 Series

  • Page 1 55-C55*-SMX55EN • Do not use in an application where the product is stopped mid-stroke, 2 Specifications 3.5 Basic Circuit ORIGINAL INSTRUCTIONS via an external stop. This product is certified to ATEX Category 2GD and therefore is • Do not use where cylinders are being synchronised to move a single suitable for use in Zones 1, 2, 21 and 22 only.
  • Page 2 55-C55*-SMX55EN 7.2 Disassembly Procedure Use appropriate pliers (tool for C-Shape Snap Ring) for installation. • Disassemble the cylinder, remove the old grease and place all the Caution parts on a clean cloth in a clean environment. When installing the retaining ring, be aware that the snap ring may come URL : http// www.smcworld.com (Global) http// www.smceu.com (Europe)

This manual is also suitable for:

C55 series