INSTALLATION

PACK OUT KIT CONTENTS

A
B
C
D
E
F
G
ILL1410-B
A
=
Ribs
B
=
O'Ring
C =
Bush
D =
Tank reservoir
(
)
E
= Tank Nut
F
=
Drain Adaptor
G =
Locking Nut
H =
Removable Plugs
I
=
Bleed Tray
J
=
Bleed Tray
Clip
s
K
=
O'Ring
INSTRUCTION MANUALS,
WARRANTY CARD
SHIELD BLEED
STOP
CABLE TIE

COOLER LOCATION

Check the proposed cooler location to ensure it is structurally
capable of supporting the weight of the cooler. If the roof is
structurally inadequate, provide an alternate load bearing
structure.
|
4
H
I
J
ROOF JACK
K
ADAPTOR
CORNER
CLIPS
(EXTRAS)
SCREWS FOR
FOOT MOUNTS
V-BELT (A57)
RUBBER WASHER
1/2" BSP
NUT & GLAND
CONDUIT
CLAMP
ADAPTOR BRASS
½"BSP to 1/4"
COMPRESSION
ILL3
707
-A
The ideal location for the cooler is in a central position on the
roof (away from sleeping areas and where people spend most
of their time) so that the duct runs are of approximately the
same length. Carefully consider neighbouring residences and
noise levels when locating the cooler, if necessary talk to the
customer and the neighbour before carrying out the installation.
A
Always locate the cooler where it will receive adequate fresh air
and not in a recess where it may be starved for air or where the
air is polluted.
B
Ensure location is a minimum of:
C
• 10' (3m) from a solid fuel heater flue,
• 5' (1.5m) from a gas flue,
D
• 17' (5m) from a sewer vent, and
E
• 2' (600mm) from a wall.
The cooler must be mounted at least 10' (3m), preferably 17'
F
(5m), away from any TV antenna or antenna cables.
G
MODEL EXT
A
=
Costilla
B
=
Junta tórica
C =
Bush roscado
D =
Tanque (depósito)
E
= Tuerca
F
=
Adaptador del drenaje
G =
Contratuerca
H =
Tapones extraíbles
I
=
Bandeja de purga
J
=
Clip de resorte
K
=
Junta tórica
Make sure the cooler is not between the antenna and the
transmission tower that is providing the television signal to the
home.
Allow adequate access to and around the cooler for
maintenance. Provision must be made for access to electricity,
water supplies and drains.
Note! Do you need to discuss the installation of items like
MANUALES DE
safety anchor points with the customer?
FONCIONAMIENTO E
INSTALACION,

ACCESS FOR SERVICING AND MAINTENANCE

TARJETA DE GARANTIA
The cooler should be installed in a position that allows adequate
access for installation, and future maintenance and servicing
activities. This should comply with installation guidelines and
any local, State and National regulations.
Consider the following for installation location:-
PROTECTOR DE
• Which has clear access to and around the cooler
DESAGOGO
• Which is clear of fixtures in line with below clearances
• Which is clear of fall edges (> 10' or 3m away)
• Which is structurally capable of supporting the weight of the
cooler and service technicians
SUJETADOR
DEL CABLE
Required clearances around the cooler for future maintenance
ILL3707-A
and servicing are shown adjacent.
H
I
J
EL ADAPTADOR
K
DE GATA PARA
TECHO
ILL1410-B
CLIPS
ESQUINEROS
X X
(EXTRAS)
TORNILLOS
DE MONTAGE
DE LAS PATAS
ILL1204-C
CORREA-V (A57)
ARANDELA
DE GOMA
TUERCA 1/2" BSP
Y ACEITUNA
ABRAZADERA
DE SILLÍN
ADAPTADOR DE
BRONCE DE
½"BSP to 1/4"
COMPRESSION
ILL3
707
-A (Spa

Advertisement