STA-RITE DB10018T Owner's Manual page 8

Battery backup systems

Advertisement

Installation
ELECTRICAL CONNECTIONS
Hazardous voltage. Can cause serious or
fatal electrical shock. Review safety instructions before
operating charger. Do not modify cord or plug.
4 STAGE LEAD-ACID
BATTERY CHARGER
BLACK TERMINAL NEGATIVE (-)
RED TERMINAL POSITIVE (+)
Figure 9 – Wiring Connections DB10018T
TABLE I - DB10018T Wiring Connections
Connect the
Positive (+) lead from the battery
Negative (–) lead from the battery
Positive lead from the charger
Negative lead from the charger
Backup sump pump
float switch (2 wires)
Positive lead from the pump
Negative lead from the pump
CHARGER/BATTERY INSTALLATION
NOTICE: An alarm, located in the junction box, auto-
matically sounds when the system runs if the alarm is in
the "Enable" position. The alarm is silenced when the
alarm switch is in the "Disable" position.
BATTERY CONNECTION
+
CHARGER CONNECTION
+
FLOAT SWITCH CONNECTION
REPLACE FUSE WITH SAME 25 AMP -
36V TYPE AND RATING ONLY
PUMP FUSE &
CONNECTION
+
DISABLE ENABLE
AUDIBLE ALARM
DISABLE WHEN LIT
BATTERY CONNECTION
+
CHARGER CONNECTION
+
FLOAT SWITCH CONNECTION
REPLACE FUSE WITH SAME 20 AMP -
36V TYPE AND RATING ONLY
20
PUMP FUSE &
CONNECTION
+
DISABLE ENABLE
AUDIBLE ALARM
DISABLE WHEN LIT
To the Junction Box's
Positive battery connection
Negative battery connection
Positive charger connection
Negative charger connection
Float switch
connection (2 wires)
Positive pump connection
Negative pump connection
Model Number DB10018T:
1. Apply two pieces of two-sided tape (provided, Key
No. 10) to the back of the junction box. Press the
junction box onto the battery box as illustrated in
Figure 9 and on Page 12 (Exploded View, Page 11).
2. Connect the charger as shown in Table I and
Figure 9.
3. Plug the charger into a 115-120 Volt AC outlet deliv-
ering at least 15 amps. Do not use a switch con-
trolled outlet. Mark circuit in main power panel
"Backup sump pump power supply; do not turn off".
4. With the charger properly connected and plugged in,
the panel on the front of the charger will show one
of the conditions illustrated in Figure 10.
4 STAGE LEAD-ACID
BATTERY CHARGER
Risk Of Explosive Gas Mixture. Read
WARNING:
owner's instruction manual before using.
CAUTION:
Charge only lead-acid batteries. Other types may
burst causing personal injury and damage. Do not Expose unit to
rain or water. To prevent electric shock, dispose of charger if cord
becomes defective. Do not smoke, strike match or cause a spark
in the vicinity of battery during charging. Connect/disconnect
leads from battery only when charger is removed from AC
Power. Charge only in ventilated areas.
BLACK TERMINAL NEGATIVE (-)
RED TERMINAL POSITIVE (+)
Green
Figure 10 – DB10018T LED Panel
Red LED - Fault indicator
See charge error table (Table II, below)
Yellow LED - Prequalification test stage is complete and testing
or charging in process
Green/Occasional Yellow - Charger turns on intermittently to
Green LED - Charging complete
NOTICE: For more detailed information, see "Charger Operation" on
Page 10.
TABLE II - Charge Error Table for DB10018T
Red LED is
1. A fault condition has occurred; indicates the
on continuously
battery failed the prequalification test or
something went wrong during the charging
process.
2. AC power to charger, but no battery
connected. Charger output leads are
unconnected, but charger is plugged into
the AC receptacle.
3. Battery voltage is below 3 Volts; the
charger does not recognize the battery
and will therefore not charge.
4. Reverse battery condition; output leads
are connected backward on the battery.
5. Overcurrent condition; Something is being
powered by the battery while it is charging.
Red
Yellow
maintain proper charge
8