PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
Setting Pulse Brew – MANUAL Pulse Brew
NOTE: If the brewer is already on the SET PULSE
BREW screen, skip steps 1 through 9, and proceed
directly to step 10.
1. Press and hold the right hidden button until the dis-
play reads SET LANGUAGE. Press the right hidden
button until the display reads REVIEW RECIPES.
2. Press YES to proceed. The display should now read
TEA 1, along with MODIFY SHOW NEXT.
3. Press and release NEXT to advance to the desired
recipe to be modified.
4. Press and release MODIFY. The display should read
BREW OZ:
5. Press and release DONE. The display should read
2 BATCHES DONE?
6. Press and release YES. The display should now
read DILUTE OZ:
7. Press and release DONE. The display should read
2 BATCHES DONE?
8. Press and release YES. The display should now
read DILUTE DELY:
9. Press and release DONE. The display should now
show the Brew Oz, Dilution Oz, and Dilution Delay
setting for the batch size just programmed. After
a 5 second delay, the display will read SET PULSE
BREW.
10. Press and release YES. The display should now
read SELECT METHOD.
11. Press and release MANUAL. With MANUAL flash-
ing, press and release NEXT.
12. The display should now read 1
batch light will be blinking. Press and release the
batch size to be modified.
13. Using (-) and (+), adjust the 1
14. When finished, press the other batch size and repeat
step # 13.
NOTE: To disable pulse brew, set 1
Brewer will automatically pulse on tea recipes with a
brew volume greater than 86.0 oz.
15. When finished setting both batch sizes, press and
release DONE.
16. The display should now read OFF TIME. Adjust
the OFF TIME using (-) and (+).
ON TIME and a
st
ON TIME.
ST
ON TIME to OFF.
ST
Page 31
17. When finished, press the other batch size and repeat
step # 16.
18. When finished setting both batch sizes, press and
release DONE.
19. The display should now read LAST ON:. Adjust the
LAST ON TIME using (-) and (+). If PREINFUSION
is desired, set the LAST ON TIME to PreI.
20. When finished, press the other batch size and repeat
step # 19.
21. When finished setting both batch sizes, press and
release DONE.
22. The display will show the three times just entered.
Press and release each batch size to display the set-
tings for that batch. If the 1
the display will read PULSE BREW DISABLED. After
a 5 second delay, the display will read 2 BATCHES
DONE?
23. If both the pulse brew settings for both batch sizes
are not correct, press and release NO to return to
the 1
ON TIME setup screen and repeat steps 13
ST
through 22.
24. If both batch sizes are correct, press YES. The display
should now read DRIP TIME. To exit to the MAIN
SCREEN, press and release the ON/OFF button.
ON TIME is set to OFF,
ST