Bunn Infusion Series Programming Manual

Bunn Infusion Series Programming Manual

Hide thumbs Also See for Infusion Series:

Advertisement

SERVICE
EVENT LOG
CARE & CLEANING
PROGRAMMING MANUAL
55503.0000 A 10/18 © 2018 Bunn-O-Matic Corporation
ACCESS
STATISTICS
GUATEMALA
ADVANCED
RECIPE
EDIT
REGIONAL SETTINGS
BREW SETTINGS
BREW SETTINGS
Bunn-O-Matic Corporation
Post Office Box 3227, Springfield, Illinois 62708-3227
Phone (217) 529-6601 | Fax (217) 529-6644
ITCB DV, ITCB Twin,
ITCB HV, ITCB HV Twin
SELECT
RECIPE
RECIPE
ETHIOPIA
DECAF
KENYA
COSTA RICA
RECIPE
VOLUME
BYPASS
SMARTWAVE
DRIP TIME
Infusion Series
Platinum Edition
SERVICE
MENU
RECIPES
MACHINE SETTINGS
SERVICE
CALIBRATIONS
IMPORT / EXPORT
EDIT
PRE-INFUSE
PULSE BREW
FRESHNESS
REVIEW
®
www.bunn.com

Advertisement

Table of Contents
loading

Summary of Contents for Bunn Infusion Series

  • Page 1 BREW SETTINGS VOLUME BYPASS PRE-INFUSE PULSE BREW BREW SETTINGS SMARTWAVE DRIP TIME FRESHNESS REVIEW PROGRAMMING MANUAL Bunn-O-Matic Corporation Post Office Box 3227, Springfield, Illinois 62708-3227 Phone (217) 529-6601 | Fax (217) 529-6644 www.bunn.com 55503.0000 A 10/18 © 2018 Bunn-O-Matic Corporation...
  • Page 2: Warranty

    AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Warranty ........................Operating Controls ....................Accessing Programming ..................Programming Lockout ....................Service Access Menu ..................... Service Access Options ..................Advanced Menu ...................... Setting a Password ....................Recipes Parameters ....................Brew Lockout ......................Modifying Recipes ....................Machine Settings ....................Recipe Review ......................
  • Page 4: Operating Controls

    When the home screen is visible, select the BREW button to begin a brew cycle on the selected side. B. PROGRAMMING Touch the BUNN logo for 2 seconds to enter the programming. C. BATCH SELECTOR SWITCHES Selecting the icon corresponding to Small, Medium, and Large batch selects the amount of product to be brewed on the selected side.
  • Page 5: Programming Lockout

    HOW TO ACCESS PROGRAMMING Touch for 2 seconds To enter programming mode, the home screen must be present on the display. Touch the BUNN logo at the top of the display for 2 seconds. The SERVICE ACCESS screen will appear on the display.
  • Page 6: Service Access Options

    PROGRAMMING (cont.) SERVICE ACCESS OPTIONS EVENT HISTORY - Select this icon to view current cycles, lifetime cycles, and the length/number of times certain components are activated. STATISTICS - Select this icon to view the amount of brew cycles per batch size. Twin models will show separate numbers for left and right brew cycles.
  • Page 7: Advanced Menu

    PROGRAMMING (cont.) SERVICE ACCESS OPTIONS EVENT HISTORY - Select this icon to view current cycles, lifetime cycles, and the length/number of times certain components are activated. STATISTICS - Select this icon to view the amount of brew cycles per batch size. Twin models will show separate numbers for left and right brew cycles.
  • Page 8: Setting A Password

    The default password for accessing the Service Menu can be reset in Regional Settings when using the password "7738" at the Password Entry screen. 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon. 3. At the PASSWORD ENTRY screen, enter the numbers: 7738.
  • Page 9: Recipes Parameters

    PROGRAMMING (cont.) COFFEE DEFAULT RECIPE PARAMETERS (Regular, Decaf, Brazil, Colombia, Costa Rica, Ethiopia, Guatemala, Kenya, Peru, Sumatra) Medium Batch Recipe Setting Small Batch Large Batch (Disabled by Default) Volume 64.0 OZ / 1.9 L 128 OZ / 3.8 L 128.0 OZ / 3.8 L Bypass (ITCB HV only) Pre-Infusion Disabled...
  • Page 10: Brew Lockout

    This is a feature that allows the user to lock out all brewing functions until the water in the tank has reached the specified READY TEMPERATURE. 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon.
  • Page 11 PROGRAMMING (cont.) DILUTION DELAY (Tea Recipes Only)- This feature allows the user to set a time when the dilution water should turn on after a brew cycle has been initiated. The user can adjust the time by touching the text field and prompting the numeric keypad or use the plus or minus butttons to increment or decrement the time.
  • Page 12: Machine Settings

    (also known as temperature lockout) feature is active. MACHINE SETTINGS HOW TO ACCESS MACHINE SETTINGS 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon. REGIONAL SETTINGS BREWER SETTINGS 3.
  • Page 13: Recipe Review

    The operator has the option to setup a recipe to include up to 3 batch sizes. Disabling all batch sizes for any given recipe will remove it from the recipe selection list at the home screen. 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon.
  • Page 14: Transfer Recipes

    14. Select YES to import all recipes. Allow time for the import to finish. 15. Touch the BUNN logo at the top of the display to return to the home screen. Remove the USB device and review the recipes for verification.
  • Page 15: Screensaver

    The time entered on this screen must fall between 5 min - 24 min. By default, the screensaver is set to 15 min. When enabled, the system will cycle through a series of BUNN graphics after the set amount of...
  • Page 16 10. Select YES to import graphics. Allow time for the import to complete. 11. Touch the BUNN logo at the top of the display to return to the home screen. Next Steps: Setting the Custom Graphic as Screensaver 1.
  • Page 17: Energy Saver

    After energy saver has been exited, the machine will not enter this mode until the next scheduled time. 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon.
  • Page 18: Freshness Time

    HOW TO MODIFY FRESHNESS TIME 1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 2. Select the ADVANCED icon. 3. At the PASSWORD ENTRY screen, select ENTER (If a password is required, enter the code at this screen).
  • Page 19: Updating Software

    PROGRAMMING (cont.) UPDATE SOFTWARE Certain folder structure must exist on a USB drive with correct naming conventions in order for the software update to be successful. In addition to folder structure, certain files are required to reside in folders within the directory. Follow the instructions to ensure folder structure and files are present before proceeding with updating software.
  • Page 20: Machine Settings

    Selecting each button will navigate the user to that respective category. The BUNN programming button will navigate the user to the home screen. BREWER SETTINGS - Machine settings allows the operator to make changes to energy saver, funnel detect, and screen saver.
  • Page 21: Transfer Machine Settings

    14. Select YES to import machine settings. Allow time for the import to finish. 15. Touch the BUNN logo at the top of the display to return to the home screen. Remove the USB device and review the machine settings for verification.
  • Page 22: Flowrate Calibrations

    1. Place a container, accurately graduated with a minimum capacity of 60 ounces, under the funnel. 2. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 3. Select the ADVANCED icon.
  • Page 23: Smart Funnel Events

    The procedure includes a 1-minute dispense of water to determine the actual flow rate. 1. Place a container, accurately graduated with a min. capacity of 128 ounces, under the dilution nozzle. 2. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS. 3. Select the ADVANCED icon.
  • Page 24: Service Messages

    When the system detects an event that requires attention, a message will appear on the display with supporting information related to the event. Selecting the BUNN logo at the top of the display will exit the to the home screen without resolving the event, but the message is recorded in "EVENT HISTORY".
  • Page 25 PROGRAMMING (cont.) USB SHORT DETECTED The USB drive is not intended to be used for anything other than machine functions. In the event of a charger or another device being inserted, this message will appear.  When this message appears, the USB port will shut down and the machine must be power cycled without any device connected to the USB port to return USB functions back to normal.

This manual is also suitable for:

Itcb twinItcb dvItcb hvItcb hv twin

Table of Contents