■ INPUT TERMINAL ASSIGNMENT
• 1 Circuit, 4-point Discrete Inputs
10
11
12
13
1ch
14
P3
NC
NC
1K
1
2
3
4
1ch
5
1ch
P1
P2
N
1 L
2L
No.
ID
FUNCTION
1
P1
Voltage Input P1
2
P2
Voltage Input P2
3
N
Voltage Input N
4
1ch 1L Ch.1, Current input 1L
5
1ch 2L Ch.1, Current input 2L
6
1ch 3L Ch.1, Current input 3L
7
DI2 +
Discrete input 2
8
DI4 +
Discrete input 4
9
COM
Discrete input common 18
POWER SUPPLY ASSIGNMENT
6
7
NC
NC
1
2
3
NC
NC
FE1
No.
ID
FUNCTION
1
NC
Unused
2
NC
Unused
3
FE1
Power ground
4
U (+)
Power input (+)
5
V (–)
Power input (–)

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.
■ EXTERNAL DIMENSIONS unit: mm (inch)
10 11 12 13
1
2
1ch
15
1ch
16
17
18
2K
3K
DI1
DI3
COM
+
+
6
1ch
7
8
9
3L
DI2
DI4
COM
+
+
No.
ID
FUNCTION
10
P3
Voltage Input P3
11
NC
Unused
12
NC
Unused
13
1ch 1K Ch.1, Current input 1K
14
1ch 2K Ch.1, Current input 2K
15
1ch 3K Ch.1, Current input 3K
16
DI1 +
Discrete input 1
17
DI3 +
Discrete input 3
COM
Discrete input common
8
9
10
NC
NC
NC
4
5
U (+)
V (–)
No.
ID
FUNCTION
6
NC
Unused
7
NC
Unused
8
NC
Unused
9
NC
Unused
10
NC
Unused
180 (7.07)
14
15 16 17 18
3
4
5
6
7
8
9
6 (.24)
18–M3 SCREW TERMINALS
for
Voltage, Current, Discrete Input
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
• 2 Circuits
10
11
12
13
P3
NC
NC
1K
1
2
3
4
1ch
P1
P2
N
1 L
No.
ID
FUNCTION
1
P1
Voltage Input P1
2
P2
Voltage Input P2
3
N
Voltage Input N
4
1ch 1L Ch.1, Current input 1L
5
1ch 2L Ch.1, Current input 2L
6
1ch 3L Ch.1, Current input 3L
7
2ch 1L Ch.2, Current input 1L
8
2ch 2L Ch.2, Current input 2L
9
2ch 3L Ch.2, Current input 3L
17 (.66)
6
7
8
9
10
1
2
3
4
5
6 (.24)
10–M3 SCREW TERMINALS
for Power
R7EWTU
1ch
14
1ch
15
1ch
16
2ch
17
2ch
18
2ch
2K
3K
1K
2K
3K
5
1ch
6
1ch
7
2ch
8
2ch
9
2ch
2L
3L
1L
2L
3L
No.
ID
FUNCTION
10
P3
Voltage Input P3
11
NC
Unused
12
NC
Unused
13 1ch 1K Ch.1, Current input 1K
14 1ch 2K Ch.1, Current input 2K
15 1ch 3K Ch.1, Current input 3K
16 2ch 1K Ch.2, Current input 1K
17 2ch 2K Ch.2, Current input 2K
18 2ch 3K Ch.2, Current input 3K
54 (2.13)
30 (1.18)
[5 (.20)]
EM-7818 Rev.2 P. 3 / 18
DIN RAIL
35mm wide

Advertisement

Table of Contents
loading

This manual is also suitable for:

R7mwtu

Table of Contents