Note: If you need to add or move adapters to satisfy the hardware requirements for Operations Console,
|
|
do this work prior to starting these steps. Do not move or remove the twinaxial adapter, if
installed, from its current input and output processor (IOP) at this time.
|
1. Access Dedicated Service Tools (DST) or System Service Tools (SST).
|
2. Select Work with System Partitions.
|
|
3. Select Work with partition configuration.
|
4. Choose Select Console Resource on the logical partition.
5. Press F9 to Change capability filter.
|
6. Select Any Console.
|
7. To select the IOP that will support your intended console, do one of the following:
|
|
v If the adapter to be used for the intended console is under the same IOP as the previous console's
|
adapter, the console IOP is already correctly tagged. Go to step 8.
v If the adapter to be used for the intended console is under a different IOP than the currently
|
configured console, place a 1 in front of the IOP to select it as the console IOP.
|
|
8. Verify an adapter for Electronic Customer Support (ECS) and an optional alternate console (twinaxial
console only).
|
v To verify the tagging for an alternate console, find the IOP with the twinaxial adapter that will be
|
used for the alternate console. It is properly tagged if you see a > (greater than) symbol on the
|
|
same line. If the > is not on this line, enter an option 2 in front of the IOP being selected as the
alternate console.
|
|
Note: The selection of an alternate console only pertains when twinaxial workstations are to be
the alternate console. The alternate console must be under a different IOP than the IOP
|
|
tagged for use by Operations Console. Operations Console cannot be used as an alternate
|
console.
v To verify the console IOP for ECS, perform the following steps:
|
|
Note: If you use Operations Console as your console type, you must also tag the same IOP used
for the console as the IOP for ECS.
|
a. Press F12 until you arrive at the Work with Partition Configuration window.
|
b. Enter a 9 in front of the partition to be tagged for ECS.
|
|
c. Look at the symbols on the same line as the tagged console IOP (the console tag is the <
symbol) for the ECS symbol, which is the + (the plus sign). If the + symbol is shown, the IOP
|
is correctly tagged for ECS. Go to step 9.
|
|
d. To tag the console IOP for ECS, enter a 1 in front of the IOP to be tagged for ECS.
Note: If you will be using Operation Console as the intended console you should now see
|
|
both a < and a + associated with the console IOP.
|
9. Press F3 to exit to the DST main menu.
10. Select Work with DST environment.
|
11. Select System Devices(skip this step if using SST).
|
12. Select Console.
|
|
13. Select Operations Console (LAN):
|
a. The Verify Operations Console Adapters window appears. This is the resource found by the
system to be used for your LAN connections. If you receive the message No valid LAN adapter
|
available you did not satisfy the hardware requirements for Operations Console. If so, use F3 to
|
|
exit to the DST main menu, then, start this topic again at step 1.
b. Press F11 to configure the adapter.
|
c. Enter the appropriate network data.
|
d. Press F7 to store the data.
|
67
Operations Console