Change from a local console directly attached to a local console on a network
|
(LAN)
|
|
Before you begin, ensure that you have satisfied all the Operations Console hardware requirements for
the PC and server.
|
|
To change from an Operations Console with a local console directly attached to a local console on a
network (LAN), you must perform steps on the PC and the server:
|
1. Change from a local console directly attached to a local console on a network (LAN) in a
|
|
non-partitioned or primary partitioned server
|
Use these instructions to change the console from a local console directly attached to a local console
on a network (LAN) in a non-partitioned or primary partitioned server.
|
2. Change from a local console directly attached to a local console on a network (LAN) in a logical
|
|
partition
Use these instructions to change the console from a local console directly attached to a local console
|
on a network (LAN) when the console to be migrated is located in a logical partition.
|
|
3. Configure the PC to use the new console type when changing from a local console directly
|
attached to a local console on a network (LAN)
Use these instructions to configure the PC to use the new console type when changing from a local
|
|
console directly attached to a local console on a network.
Change the console from a local console directly attached to a local console on a network (LAN) in a
|
non-partitioned or primary partitioned server: To change from an Operations Console with local
|
|
console directly attached to a local console on a network (LAN), follow these steps on the server using
the existing console:
|
1. Access Dedicated Service Tools (DST) or System Service Tools (SST).
|
|
2. Select Work with DST environment.
|
3. Select System Devices (skip this step if using SST).
|
4. Select Console.
5. Select Operations Console (LAN). The Verify Operations Console Adapters window. This is the
|
resource found by the system to be used for your LAN connection.
|
|
If you get a message stating that the LAN adapter was not found, you have not satisfied the
hardware requirements for Operations Console.
|
6. Press F11 to configure the adapter.
|
7. Enter the appropriate network data.
|
8. Press F7 to store the data.
|
|
9. Press F14 to activate the adapter for use by Operations Console.
|
10. Press F3 to return to the DST main menu.
|
The system is now configured for use by Operations Console local console on a network.
|
The iSeries system value QAUTOCFG must be set to ON. Use one of the following to verify or set this
system value on the iSeries server:
|
v Use the WRKSYSVAL QAUTOCFG OS/400 command.
|
v During a manual IPL, in the IPL Options window, select Y for Set major system options. Then, for
|
|
Enable automatic configuration, select Y.
Continue with Configure the PC to use the new console type.
|
|
Change the console from a local console directly attached to a local console on a network in a logical
partition: To change from an Operations Console with a local console directly attached to a local console
|
on a network (LAN), follow these steps on the server using the existing console:
|