Zigbee Network Communication Test; Unicast Test; Unicast Between The Terminal And The Coordinator With Short Addresses - Ebyte E180-DTU User Manual

Hide thumbs Also See for E180-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
Similarly, routing nodes and terminal nodes also join a specific ZigBee network according to the above method. If the
node type is unchanged but needs to join to another ZigBee network, the Enter button
configuration also needs to be clicked. Modify the network parameters before write the parameters, finally restart, and
then join the new ZigBee network.

7.3 ZigBee network communication test

7.3.1 Unicast test

7.3.1.1 Unicast between the terminal and the coordinator with short addresses

(1) Enter the configuration mode, configure the target network address, and change the target network address of the
coordinator to the local short address of the terminal (0xFCFA). The target network address of the terminal is 0 by
default, and 0 is the network short address of the coordinator (the network short address of the coordinator is always 0).
At this time, no modification is needed. If it communicates with a non-coordinator node, it needs to be modified
(modified it to the target Node's network local short address).
(2) After the target addresses between the nodes are configured, click "Enter Transmission Mode", and a message
box prompts "Enter transmission mode successfully ". Then confirm whether the module is in transmission mode before
communication, and they can only communicate in transmission mode. Input data in the sending area and click send, you
can see the received data in the message box of the terminal node.
Copyright ©2012–2019,
C
hengdu Ebyte Electronic Technology Co.,Ltd
E180-DTU(ZG120-485) Usermanual
next to the node type
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zg120-485

Table of Contents