CAN bus network and WiFi network. ECAN-W01S has a built-in 120 ohm resistor, which can be enabled by dialing; Support the operation within the temperature range of - 40 ℃~85 ℃. It has a 10M Ethernet interface.
Manual 2. Quick Get Start You need quasi ECAN-W01S * 1, power adapter * 1, network cable * 1, 2.4GWiFi antenna * 1, CAN analyzer * 1; 1、 The factory default of the device is AP mode, the SSID is ECAN-W01S-XX, and the password is 12345678.
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual 3. Technical Indicators 3.1. General specifications Serial No Project Specifications 8V~28VDC, over 28V may burn out, 12V or 24V power supply supply voltage is recommended Mesh port Standard RJ45, supporting 10Mbps specification WiFi IEEE802.11a/b/g standard...
Page 7
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual Identifica Serial No Function description tion name WiFi antenna SMA interface Ethernet interface, standard RJ45 interface, connected ETHERNET to PC Power positive interface, 5.08 phoenix head, (default 8-28V), 12V/24V recommended Power supply cathode interface 5.08 Phoenix head...
TCP server supports up to four TCP sockets. By default, the device is in AP mode. The SSID is ECAN-W01S-XX-XX-XX-XX (followed by the device MAC address). The default secret key is 12345678.
0, it initiates a connection with a random port each time. (3) In the same LAN, if ECAN-W01S is set as a static IP, please keep the IP and gateway of ECAN-W01S in the same network segment, and set the gateway IP correctly, otherwise normal communication will not be possible.
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual (2) This mode is usually used in data transmission scenarios where multiple network devices need to communicate with modules and do not want to use TCP due to high speed and frequency.
Page 11
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual The value that can be filled in is 1~255. When the CAN port does not receive new data frames within the time defined by the "packet time Subcontractin interval" (unit: ms) and the number of packet...
Page 12
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual Because the speed of Ethernet is much higher than that of CAN transmission, if the amount of data received by Ethernet is too large, CAN needs to buffer transmission, which can ensure no frame...
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual 4.3. Features 4.3.1. CAN filtering CAN filtering is divided into software filtering and hardware filtering. 4.3.1.1. Software filtering The upper limit value and lower limit value of received extended frame ID set jointly determine the range of extended frame ID to be received;...
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual filter group in the mask bit mode can have two filters. Each filter contains a 16 bit identifier register and a 16 bit mask register; In identifier list mode, all four registers are used as identifier registers.
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual 4.3.3. Modify baud rate online The device supports online adjustment of the baud rate through the Ethernet port in the TCP Server mode without entering the configuration software. The command format is as follows...
3F 09 FF 00 00 00 00 FF 00 00 00 00 4.3.4. Heartbeat function In the network transparent transmission mode, users can choose to let ECAN-W01S send heartbeat packets. The heartbeat packet can be sent to the network server. The main purpose of sending to the network side is to maintain the connection with the server.
The timeout restart (no data restart) function is mainly used to ensure the long-term stable operation of ECAN-W01S. When the link has not received and sent data for a long time, ECAN-W01S will restart after exceeding the set time, so as to avoid the impact of abnormal conditions on communication.
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual 4.5. Disconnection reconnection Disconnection reconnection: the device requests connection periodically after disconnection to ensure that the connection can be restored in case of accidental disconnection (note that the device is not restarted);...
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual 4.7. Restore factory settings The device has the function of pressing the key to restore the factory settings. To restore the factory settings of the hardware, long press the reload key for more than 5s.
Chengdu Ebyte Electronic Technology Co.,Ltd ECAN-W01S User Manual transmission station will be equipped with one by one. Please understand. 6. Revision History edition Revision Date Revision description Maintainer 2022-06-10 First edition 7. About us Sales hotline: 4000-330-990 Company telephone: 028-61399028 Technical support: support@cdebyte.com...