Need help in finding why it keeps running g
1 comments:
Mr. Anderson
February 10, 2025
The Everbilt LTS250A may keep running due to the following reasons:
1. Check valve is not installed – Install the check valve properly as per the owner's manual. 2. Check valve is jammed – Unplug the pump, open the discharge line, and clean the check valve.
These issues can cause the pump to cycle ON and OFF even when there is no water in the sink.
Page 1
THANK YOU We appreciate the trust and confidence you have placed in Everbilt Utility Pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home...
WARNING: Risk of fire or explosion. Pump water only with this pump. Do not use this pump in the presence of flammable or explosive vapors. CAUTION: Motors run hot. Do not touch the motor housing during operation. Utility Sink Pump - LTS250A, SBA025HPACK Problem 1: Pump does not run when water flows in from the sink. Possible Causes Corrective Action 1.
2. Clean the strainer or hose. 3. The discharge hose is too long. 3. The hose length should be no longer than 25' 4. Incorrect Garden hose on 4. Use standard garden hose, not "expandable" hose. outlet/discharge. Everbilt Utility Pump Troubleshooting Guide...
3. The hose is kinked or coiled tightly. "expandable" hose. 4. Unplug the pump. Remove the Strainer base and flush with clean 4. The Strainer Base is clogged with debris. water until it is clean. Everbilt Utility Pump Troubleshooting Guide...
4. There is trapped air inside the pump, a 4. If a check valve is installed, drill a 1/8" hole between the pump condition called "airlock". discharge and check valve. 5. The hose is loose. 5. Secure the hose. Everbilt Utility Pump Troubleshooting Guide...
Need help?
Do you have a question about the LTS250A and is the answer not in the manual?
Questions and answers
Need help in finding why it keeps running g
The Everbilt LTS250A may keep running due to the following reasons:
1. Check valve is not installed – Install the check valve properly as per the owner's manual.
2. Check valve is jammed – Unplug the pump, open the discharge line, and clean the check valve.
These issues can cause the pump to cycle ON and OFF even when there is no water in the sink.
This answer is automatically generated