Summary of Contents for Everbilt SFP71

  • Page 1 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you...
  • Page 2: Table Of Contents

    Table of Contents Identification Plate ....... . . 7 Safety Information ........2 Insulation Test .
  • Page 3: Warranty

    Safety Information (continued) WARNING: To reduce the risk of electrical shock, the CAUTION: Do not wear loose clothing that may become pump must be properly grounded in accordance with the entangled in moving parts. Always wear appropriate safety United State National Electric Code (NEC), or the Canadian gear, such as safety glasses, when working on the pump or Electrical Code (CEC) and all applicable state, and local piping.
  • Page 4: Pre-Installation

    □ Single Phase: Permanent Split Capacitor (PSC) includes overload protection in motor PERFORMANCE Motor HP Model GPM at Total Feet of Head Max Head 5 ft. 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 60 ft. SFP71 SFP102 NOTE: To convert to feet of head, multiply by 2.31.
  • Page 5: Electrical Specifications And Dimensions

    Pre-Installation (continued) ELECTRICAL SPECIFICATIONS AND DIMENSIONS Models Volt Ph Full Load Amps Outlet Hose O.D. (in.) Outlet (in.) L (in.) W (in.) H (in.) SFP71 12.0 1.75 in. 1 in. (F) NPT 15.75 7.75 8.06 SFP102 1.75 in. 1 in. (F) NPT 15.75...
  • Page 6: Installation

    Installation SUBMERGENCE ELECTRICAL CONNECTIONS □ If the pump is used in a decorative water display, the pit that □ The motor is an oil-filled, single-phase, permanent, split- the pump is used in must be deep enough to allow the pump capacitor type with built-in automatic overload protector.
  • Page 7: Operation

    Operation WARNING: Unit must be full of fluid before operating. Do not run dry, or against a closed discharge. Do not pump dirty water or abrasive liquids. To do so will cause pump failure and will void the warranty. WARNING: The motor runs hot. Avoid touching the motor case. Contact during operation may cause a burn. CHECKING VOLTAGE AND PHASE □...
  • Page 8: Storage

    Maintenance (continued) LUBRICATION STORAGE SHORT TERM NOTE: Refer to the Replacement Parts section for illustrations of part and part numbers referenced in this □ Pumps are manufactured for efficient performance following section. short inoperative periods in storage. For best results, pumps can be retained in storage, as factory assembled, in a dry □...
  • Page 9: Perform A Pressure Test

    Maintenance (continued) PERFORM A PRESSURE TEST 3. Apply pipe sealant to the pressure gauge assembly and tighten into the hole. NOTE: Refer to the Replacement Parts section for 4. Pressurize the motor housing to 6 PSI. illustrations of part and part numbers referenced in this 5.
  • Page 10: Motor And Seal Service

    Maintenance (continued) MOTOR AND SEAL SERVICE NOTE: Refer to the Replacement Parts section for illustrations of part and part numbers referenced in this section. DISASSEMBLY AND INSPECTION 1. Remove the screen, volute, and impeller as previously stated 9. Mark the location of the overload in relation to the bearing and drain oil from the motor housing.
  • Page 11: Reassembly

    Maintenance (continued) REASSEMBLY NOTE: Refer to the Replacement Parts section for illustrations of part and part numbers referenced in this section. 1. Assemble the bearing sleeve (9) onto the motor (10), locating the overload as noted (or at the 11 o’clock position as viewed Seal from the motor end), with the four motor bolts.
  • Page 12: Power Cable Connection

    Maintenance (continued) POWER CABLE CONNECTION 1. Place the gland nut (17), friction ring (16), and grommet (15) Power Leads onto the cord and slide the cord through the housing end (19). L1 L2 2. Place the O-ring (23) into the groove on the housing end piece (19) and slide the end piece onto the motor housing (25) being careful not to damage the O-ring.
  • Page 13 Troubleshooting (continued) Problem Solution Probable Cause □ Check all electrical connections for The pump hums but does not run. The voltage is incorrect. security. □ Have an electrician measure the cur- rent in the motor leads. If the current is within ±20% of locked rotor Amps, the impeller is probably locked.
  • Page 14 Troubleshooting (continued) Problem Solution Probable Cause □ Check all electrical connections for secu- The pump shuts off and turns on The voltage is incorrect. independent of the switch (trips thermal rity. Have an electrician measure current overload protector). in motor leads. If current is within ±20% of locked rotor Amps, the impeller is CAUTION: The pump may start probably locked.
  • Page 15: Replacement Parts

    Replacement Parts See Parts list on next page. HOMEDEPOT.COM Please contact 1-844-883-1872 for further assistance.
  • Page 16 Replacement Parts (continued) Part Description Part Number Part Number Qty. Part Description Part Number Part Number Qty. Volute Motor Housing End Cover Impeller HDSFP7102 HDSFP1002 Hex Nut Slotted Set Screw Lock Washer Lock Washer Pump Support Shim HDSFP7105 HDSFP7105 O-ring HDSFP7123 HDSFP7123 V-ring...