Adjustments

Adjust Manifold Relief Valve (R1 and R2)

The hydraulic reel circuit is equipped with a relief valve.
Valve (R1) is preset at the factory to 3000 PSI and valve
(R2) to 2000 PSI. However, an adjustment may be re-
quired if the setting proves to be off after testing (see
TESTING). If an adjustment is required proceed as fol-
lows:
WARNING
Never adjust the relief valve with the hydraulic
system pressurized. Hydraulic oil may spray out
of the valve with the cap off. Personal injury may
result. Always install the cap and tighten before
pressurizing the system.
Note: Do not remove the relief valve from the hydrau-
lic manifold for adjustment.
1. Remove cap from the relief valve with an allen
wrench.
Note: An 1/8-turn of the adjustment socket is about 50
psi (3.5 bar), or 1 turn is about 400 psi (27.6 bar).
2. To increase pressure setting, turn the adjustment
socket inside the valve 1/8 of a turn clockwise.
3. To decrease pressure setting, turn the adjustment
socket inside the valve 1/8 of a turn counterclockwise.
Reelmaster 5200-D/5400-D
1. Relief valve cap
4. Install and tighten cap to valve. Retest pressure set-
ting (see Testing).
Page 4 - 33
2
2
Figure 27
2. Adjustment socket
Hydraulic System