14.9 Adjustment to different
types of gas
WARNING!
Let only an authorized
person do the adjustment to
different types of gas.
The appliance is set for
liquid gas. You can change it
to natural gas, with the
correct injectors.
The gas rate is adjusted to
suit.
WARNING!
Before you replace the
injectors, make sure that the
gas knobs are in the Off
position. Disconnect the
appliance from the electrical
supply. Let the appliance
cool down. There is a risk of
injury.
The appliance is set to
default gas. To change the
setting choose a pipe holder
from the list. Always use the
gasket sealing.
A
A. Gas connection end
B. Natural Gas pipe holder
C. LPG pipe holder
14.10 Hob injectors
replacement
Replace the injectors when you change
the gas type.
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
B
C
3. Remove the injectors with a socket
spanner 7.
4. Replace injectors with the ones
necessary for the type of gas you
use.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply.
You can find this plate in
the bag supplied with the
appliance.
If the supply gas pressure is not constant
or it is different from the necessary
pressure, install an applicable pressure
adjuster on the gas supply pipe.
14.11 Adjusting the minimum
gas level on the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there
is no access to the bypass screw
dismount the control panel before
adjustment start.
3. With a thin and flat screwdriver adjust
the bypass screw A.
The model determines the position of
the bypass screw A.
A
A