Encoder Connection - Bosch Rexroth IndraDyn A Series Project Planning Manual

Asynchronous motors mad/maf
Table of Contents

Advertisement

Rexroth IndraDyn A

Encoder Connection

DOK-MOTOR*-MAD/MAF****-PR03-EN-P
Out
In
Fig. 13-10: Connection diagram for explosion-protected areas
A 15 meter-long connection cable is connected with the explosion-
protected motors. This connection cable has been connected with the
encoder at the factory. After motor assembly, this cable must be
connected with the drive device.
Danger of explosion due to improper handling
when connecting the encoder!
⇒ The junction to/on the motor drive device must be
located outside of the area subject to explosions.
DANGER
Notes:
Observe the following when connecting the encoder:
• The encoder housing on the motor may no longer be
opened! Do not remove any of the screws on the encoder
housing.
connected with the motor encoder at the factory.
• Work may be carried out only if the electrical system is not
under power.
• Heed the information on projecting planning in respect of
the drive device, and the information on connector
assignment in chapter 8.7 "Encoder Connection".
Motors for Hazardous Areas
MAx_Power_Connect_ATEX_EN.EPS
The
connection
cable
13-13
M
has
already
been

Advertisement

Table of Contents
loading