28/57
Assembly
6.7

Electrical connection

6.7.1

Connection cable on primary part

Wire designation of power connec‐
tion cable
Bosch Rexroth AG R911389762_Edition 04
The electrical connection of the primary part is done via two shielded connec‐
tion cables, which are fixed with the primary part. These connection cables
can be shorted according to the machine requirements and be prepared with
a connector or a clamping point.
For connection of primary parts to the Rexroth controller, Rexroth offers a
wide range of connectors and ready-made cables as accessories. All cables
and connectors are perfectly fitted for the products and their requirements.
For connection of the primary part with these extending cables, a connector
has to be applied at the connection cables. Please note that self-assembled
cables or cable systems of other manufactures may not comply with these re‐
quirements. Bosch Rexroth shall not be held responsible for resulting mal‐
functions or damages.
Ensure that the complete machine fulfills all necessary regula‐
tions, especially EN 60204.
Connection cable power
Connection cables temperature sensors
Fig. 6-12:
Connection cable on primary part
ML3P connection cables
Connection ca‐
Cable
bles
lengths
1 m
Power
3 m
1 m
Temperature
3 m
Tab. 6-9:
ML3P connection cables
Power
L1
3-phase
L2
L3
Grounding con‐
PE
ductor
Shield
Tab. 6-10:
Wire designation of power connection cable
ML3 Self-Cooled Linear Motors
Suitable for drag chains ML3P03 ML3P06 ML3P11
No
yes
No
No
Wire color / - designation
BK / 1
BK / 2
BK / 3
GNYE
Metal braiding
-
-
-
-
-
-

Advertisement