Epever MPPT Tracer1206AN User Manual page 25

Solar controller
Hide thumbs Also See for MPPT Tracer1206AN:
Table of Contents

Advertisement

C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥ Discharging Limit
Voltage;
E. Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage;
F. Low Voltage Disconnect Voltage ≥ Over Discharging Protection Voltage (BMS)+0.2V
The required accuracy of BMS is no higher than 0.2V. We will not assume
responsibility for the abnormal when the accuracy of BMS is higher than 0.2 v.
CAUTION
4)
Load mode setting
When the LCD shows the above interface, operate as follows:
Operation:
Step1: Press the SELECT button to browse the load mode interface.
Step2: Press and hold the ENTER button until the load mode interface begins to flash.
Step3: Press the SELECT button to modify the load mode.
Step4: Press the ENTER button to confirm.
① Load mode
1**
100
Light ON/OFF
101
The load will be on for 1 hour
since sunset
102
The load will be on for 2 hours
since sunset
103
The load will be on for 3 ~13
~113
hours since sunset
114
The load will be on for 14 hours
since sunset
115
The load will be on for 15 hours
since sunset
116
Test mode
117
Manual mode(Default load ON)
Timer 1
2**
2 n
Disabled
201
The load will be on for 1 hour before
sunrise
202
The load will be on for 2 hours before
sunrise
203
The load will be on for 3 ~13 hours
~213
before sunrise
214
The load will be on for 14 hours before
sunrise
215
The load will be on for 15 hours before
sunrise
2 n
Disabled
2 n
Disabled
21
Timer 2