Saving Settings Permanently And Resetting To Default Values; Tab. 57 Save Settings In Eeprom; Tab. 58 Resetting The Settings To Their Default Values - Jetter JXM-IO-EX30 User Manual

Expansion module
Hide thumbs Also See for JXM-IO-EX30:
Table of Contents

Advertisement

Jetter AG

7.6 Saving settings permanently and resetting to default values

The following parameters are permanently stored in the EEPROM:
PDO Mapping
All IO interface assignments and parameters
Producer heartbeat time
Saving
Index
0x1010
Tab. 57: Save settings in EEPROM
Resetting the settings to their default values
INFO
Index
0x1011
Tab. 58: Resetting the settings to their default values
Setting parameters
The parameters are set as follows:
1.
The vehicle controller configures the parameters of the JXM-IO-EX30.
2.
The vehicle controller saves the settings via index 0x1010 in the EEPROM.
3.
The vehicle controller reads the CRC via index 0x4556, subindex 1 and saves this value lo-
cally remanently.
4.
After a restart of the JXM-IO-EX30 the vehicle controller compares the locally stored CRC
value with the value in index 0x4556, subindex 1. If the values do not match, parameteriza-
tion must be restarted.
INFO
JXM-IO-EX30 User Manual
Subindex
Description
0
Number of supported entries
1
Saving all parameters
When the specific signature 0x65766173 ("save") is written, the pa-
rameters are saved.
Loading the settings from the EEPROM
During bootup, the last saved settings are automatically loaded.
During a firmware update, the settings may be reset to the default values.
Subindex
Description
0
Number of supported entries
1
Command register
When the specific signature 0x64616F6C ("load") is written, all set-
tings are reset to the default values.
The changes to the indices 0x1010 and 0x1011 only become active after a
restart.
Programming | 7
Type of
Type
access
U8
R
U32
R/W
Type of
Type
access
U8
R
U32
R/W
Default
value
1
Default
value
1
1
41 / 63

Advertisement

Table of Contents
loading

Table of Contents