Jetter JXM-IO-EX30 User Manual page 12

Expansion module
Hide thumbs Also See for JXM-IO-EX30:
Table of Contents

Advertisement

Jetter AG
Blinking pattern of
the amber LEDs
Detecting LED
faults
JXM-IO-EX30 User Manual
Color
Blinking pattern
Orange
Permanently ON
Orange
Permanently OFF
ON
Orange
OFF
In the power-up phase (bootup), all amber LEDs light up for 2 seconds and are
then off for one second. This lets you detect functional errors of individual LEDs.
Description
I/O signal active
Current input: Current is applied
Voltage input: Voltage is applied
PNP input: H level
NPN input: L level
PWM output: Dutycycle > 0%
Digital output: H level
No I/O signal active
Current input: No current applied
Voltage input: No voltage applied
PNP input: L level
NPN input: H level
PWM output: Dutycycle = 0%
Digital output: L level
I/O error:
ERROR
CONFIG
OVERVOLTAGE
200 ms
OVERCURRENT
200 ms
SUPPLY_FAULT
VEXT_SEN
OPEN_CIRCUIT
CC_UNLOCK
Product description | 3