Disconnect the machine from AC power before servicing and when not in use. l If the supply cord is damaged, contact your local Antari dealer for replacement. l This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth.
Step 1: Place the machine on a flat surface and in a suitably large area with at least 50 cm of open space around the machine. Step 2: Fill the fluid tank with Antari approved fluid. Step 3: Connect the machine to a suitably rated power supply. To determine the power requirement for the machine, refer to the label on the back of the machine.
Fan 21 – 100% Fluid Only use Antari FLG water-based liquid for the F-2 Fazer. The machine is tested and calibrated with this liquid to get the best output performance. Warranty will be voided if any other type of liquid is used, improper use of liquid may lead to machine failure and malfunction.
Indicates heater is not working properly Heater Error If above message shows on the display, unplug the machine and stop operation immediately. Contact your local Antari dealer for advice Technical Specifications Input Voltage US model: AC 100-120V, 50/60 Hz EU model: AC 220-240V, 50/60 Hz...
Need help?
Do you have a question about the F-2 Fazer and is the answer not in the manual?