Download Print this page

Configu.:programmes; Inputs=2; 5.2. Outlets; Num. Of Input - Progres AMBITROL 100 Instruction Manual

Advertisement

8

5.2. OUTLETS

CONFIGU.:Programmes=

Inputs=2

If the option 3 (INPUTS) is chosen from the
menu of CONFIGURATION we will be able to
configurate the analogical outlets with the following
screen.
It is not necessary to configurate the outlets by
relay.
Num. of outlet=0
(analogical 0-10v)
The maximum number of analogical outlets is 3
(optionally 4) in Model 102 and 8 in Model 103.
The analogical value goes from 0 to 10 V. and it
corresponds to the 0 to 100% that will be shown on the
screen as value of outlet.
This outlet is normally connected to controllers
of
speed,
lightness,
controllers, etc.
It is possible that, for example, a speed
controller needs to work from 2 to 10 volts, for the
engine to start well at low speed; then, in the minimum
tension it will be given a value of 02.0 volts (in this
case the 0% corresponds to 0 volts and the 1% to 2
volts).
Num. of outlet= 3
Minimum tension 00.0V
We can also fix beforehand the level of
maximum tension.
Num. of outlet= 3
Maximum tension 10.0V
The equipment which receives the tension may
need the inverted sign (from 10 to 0V.) in this case,
enter in minimum tension 10.0V and in maximum
tension 00.0V.
To escape, enter the outlet "0" or press "FUN" or
"CON".
5.3. PROGRAMMES
CONFIGU.:Programmes=1
Inputs=2
Choosing option 1 (Programmes) from the menu
of
CONFIGURATION
programmes, but it is necessary to configurate the
1
Outlets=
3
powered
valves,
hatches
Outlets=
3
you
can
configurate
inputs and outlets before, as they are related to the
programme.
First, we can see the following screen asking for
the number of PROGRAMME we want to access, give
the
number
and
"ENTER".
capacity for 10 programmes.
Num. of programme= 00
(to configurate)
Once the number has been entered, we can see
the following screen.
P05
Type of working=1
In
the
question
programme" we have to take into account what it is
going to control, because the number of type is what
conditions totally the questions and answers of the
programme.
(At the end of this Manual there is a detailed
description of every TYPE).
If the value 00 is entered, it erases all the data
of this programme.
Once the type is entered, it will ask for the text
and a number; these will be used to identify the type of
control and where the programme is working.
P05
Text=00
The list of texts is as follows.
01- TERM (Thermostat)
02- CALE (Heating)
03- VENT (Ventilation)
04- HUMI (Humidification)
05- VTNA (Window)
06- REFR (Refrigeration)
07- NAVE (Premise)
08- ZONA (Area)
The
number
is
programmes which have the same function, for
example several thermostats which will be given
different numbers to differenciate them.
A programme normally needs to read from some
sounds (inputs) placed in the installation to compare
that value with the programmed one and in this way
act on the corresponding outlet.
Every programme can read one or two sounds,
if there are two it takes the average .
P05
TERM-1
Num. of inputs= 00
The
equipment
"type
of
working
of
Number=0
09- ALAR (Alarm)
10- TIEM (Time)
11- AGUA (Water)
12- ALIM (Feed)
13- CONT (Control)
14- ILUM (Lighting)
15- SALA (Room)
16- -A
used
to
identify
different
has
the

Advertisement

loading

This manual is also suitable for:

Ambitrol 102Ambitrol 103