F5: Configuration - Progres AMBITROL 100 Instruction Manual

Advertisement

F1:
Programmes
F2:
Curves
F3:
Record
F4:
Anomalies
F5:
Configuration
F6:
Miscellaneous
To
choose
corresponding number and "ENTER". When pressing
the number you acced to directly to one of the three
above seen screens (the screen also changes with the
key "FUN").
DESCRIPTION OF THE FUNCTIONS
PROGRAMMES
With this function you access to the most
important data of every working programme.
CURVES
Here the values are given in order to form a
curve to be followed by the programme.
RECORD
Statistic of the last seven days for every one of
the programmes.
ANOMALIES
Record of the different anomalies that can take
place in the installation.
CONFIGURATION
Here the equipment is configurated to adapt it to
the necessities of the installation to be controlled. This
is normally done by the installator. It is important not to
access this function without an exact knowledge of
what you are going to modify.
VARIOUS
To leave the alarm in the stand by position or
not, set the clock or leave the equipment temporarily in
stop.
In some screens some letters with inverted
background will appear and they have got the following
meaning.
P= Programme: Programme number.
C= Curve: Activated curve (1) or deactivated (0)
E= Input: Value of the sensor/s of input.
S= Outlet: State of the outlet.
TYPES OF WORKING
We call types of working to the different ways of
working the equipment allows.
a
FUNCTION,
press
TYPE-01
Input of sensors, outlet by relay.
When the value of the sensor is lower than the
value of reference, the outlet is activated until it
overcomes it and reaches the value of the differential.
Examples: Heating, Humidification, etc.
TYPE-02
Input of sensors, outlet by relay.
When the value of the sensor is higher than the
value of reference, the outlet is activated until It
its
reaches the value of the differential.
Examples: Refrigeration, drying, etc.
TYPE-03
Timetable programme, outlet by relay.
When
the
reached, the outlet is activated, finishing when there is
no more time of activation left. Up to 99 periodical
activations can even be programmed, at the same
time. The programme can also be started obeying any
other programme.
Example:
humidification by time, when the humidity of a certain
value decreases, etc.
TYPE-04
Input of sensors, analogical outlet (0-10 V).
Every programme is given a reference, a
proportional band and a maximum and minimum
percentage of outlet. When the value of the sensor is
lower
than
the
proportionally from the minimum to the maximum,
obtaining this last one when the sensor reaches the
value of reference minus the programmed proportional
band.
Example: Proportional heating.
TYPE –05
Input of sensors, analogical outlet (0-10 V)
The
programme
proportional band and a maximum and minimum
percentage of outlet. When the value of the sensor is
higher
than
the
proportionally from the minimum to the maximum,
obtaining this last one when the sensor reaches the
value of reference plus the programmed proportional
band.
Example: Forced ventilation.
TYPE-06
Input of sensors, outlet by two relays (open -
close).
Special type to work on windows with lathe so
that the natural ventilation can be made. When the
temperature is higher than the reference, some timings
are made, one of stop and another of opening. The
same happens to close, when the temperature is lower
than the reference minus the differential.
TYPE-07
day
and
time
programme
Lighting,
feeding,
reference,
the
outlet
is
given
a
reference,
reference,
the
outlet
3
are
irrigation,
increases