TYPE 6
Input of sensors, outlet by two relays (open -
close).
Special type to work on windows with lathe so
that the natural ventilation can be made.
When the temperature is higher than the
reference, some timings are made, one of stop and
another of opening.
The
same
happens
temperature is lower than the reference minus the
differential.
CONSULT
P01
VTNA-0 E 24.8 ºC
S Open
PROGRAMME
P01
VTNA-0 C0
Reference= 24.0 ºC
Differential= 02.0 ºC
Tim. Open= 05 s
Pause Open = 128 s
Tim. Close= 100 s
Pause Close= 100s
Manual (Yes/no)= No
CURVE1
P01
VTNA-0 C1Pto1
Pos=000
Pos=045
Pos=000
Pos=000
CONFIGURATION
P01
VTNA-0
Type of working= 6
Text= 05
Num. of inputs= 8 7
Num. of outlet= 04(5)
Conditioning Pro.= 00
Affects in code= 00
RECORD
VTNA-0 21/06
24.9
23.4
to
close,
when
Ref=24.8 ºC
Ref=21.3 ºC
Ref=000 ºC
Ref=000 ºC
Number= 0
21.7 ºC
High alarm
20.0
15.0
10.0
Low
5.0
alarm
the
OPEN
STOP
CLOSE
19
REFERENCE
DIFFERENTIAL