232 MONITOR PLUS
factory settings by pressing the RESET
key, and then [D]).
To save and recall communication
settings on the 232 Monitor Plus:
1. Set the parameters you would
like to save.
2. Press START/STOP to leave
the Configure Menu and go to
the View Menu.
3. Press SAVE CONFIG [Y] and
Enter configuration number to save
1-3=user defined
hit [RETURN] when done
see the following message on
the prompt line.
4. Press a number from 1-3.
5. Press RETURN.
6. The configuration is saved.
See LOAD CONFIG (pp. 11-12) for
more information.
SET DATE [V]
Pressing [V] allows you to set the
internal clock on the Monitor Plus.
Start Trigger
Stop Trigger
LEFT/RIGHT ARROWS to set flashing values.
UP/DOWN ARROWS to change selection. PAGE
UP/DN for next page.
Hit [START/STOP] to continue.
22
OFF OR
OFF
[START] to continue.
You must enter two digits each for
hours/minutes/seconds and
day/month/year.
SET TRIGGER [5]
Once you've created an edit string
or modem control mask, it can act as
a trigger to begin data collection.
Press SET TRIGGER and you get the
screen shown below.
Interpret the screen as follows:
Start Trigger
When you set the value to anything
besides "Off," the 232 Monitor Plus
will actively search all incoming data
for that value. When it finds a
match, it will begin collecting data.
String1-TD
232 Monitor Plus will look for
string1 on the TD line trigger.
String1-RD
232 Monitor Plus will look for
string1 on the RD line.
Modem Ctl Mask1
232 Monitor Plus will look for the
high or low states of the RS, CS, DS,
CD, DT, and RI lines. When they
StopTrigger
Off, String1-TD,
String1-RD, Modem Ctl
Mask1
None